SDS

Exposure controls/personal protection8 .
TWA: 25 ppm 8 hour(s).
OSHA PEL 1989 (United States, 3/1989). Notes: See Table Z-2.
TWA: 170 mg/m³ 8 hour(s).
TWA: 25 ppm 8 hour(s).
OSHA PEL Z2 (United States, 11/2006).
AMP: 300 ppm 5 minute(s).
CEIL: 200 ppm
TWA: 100 ppm 8 hour(s).
Titanium Dioxide
ACGIH TLV (United States, 1/2009). Notes: Substance identified by
other sources as a suspected or confirmed human carcinogen.
1996 Adoption Substances for which the TLV is higher than the
OSHA Permissible Exposure Limit (PEL) and/or the NIOSH
Recommended Exposure Limit (REL). See CFR 58(124) :36338-
33351, June 30, 1993, for revised OSHA PEL. Refers to Appendix A -
- Carcinogens.
TWA: 10 mg/m³ 8 hour(s).
OSHA PEL (United States, 11/2006).
TWA: 15 mg/m³ 8 hour(s). Form: Total dust
OSHA PEL 1989 (United States, 3/1989).
TWA: 10 mg/m³ 8 hour(s). Form: Total dust
Use a properly fitted, air-purifying or air-fed respirator complying with an approved
standard if a risk assessment indicates this is necessary. Respirator selection must be
based on known or anticipated exposure levels, the hazards of the product and the safe
working limits of the selected respirator.
Safety eyewear complying with an approved standard should be used when a risk
assessment indicates this is necessary to avoid exposure to liquid splashes, mists,
gases or dusts.
Personal protective equipment for the body should be selected based on the task being
performed and the risks involved and should be approved by a specialist before handling
this product.
Personal protection
Eyes
Skin
Respiratory
:
:
:
Chemical-resistant, impervious gloves complying with an approved standard should be
worn at all times when handling chemical products if a risk assessment indicates this is
necessary.
Hands :
Engineering measures :
Use only with adequate ventilation. If user operations generate dust, fumes, gas, vapor
or mist, use process enclosures, local exhaust ventilation or other engineering controls
to keep worker exposure to airborne contaminants below any recommended or statutory
limits.
Hygiene measures :
Wash hands, forearms and face thoroughly after handling chemical products, before
eating, smoking and using the lavatory and at the end of the working period. Appropriate
techniques should be used to remove potentially contaminated clothing. Wash
contaminated clothing before reusing. Ensure that eyewash stations and safety showers
are close to the workstation location.
Recommended monitoring
procedures
:
If this product contains ingredients with exposure limits, personal, workplace atmosphere
or biological monitoring may be required to determine the effectiveness of the ventilation
or other control measures and/or the necessity to use respiratory protective equipment.
Environmental exposure
controls
:
Emissions from ventilation or work process equipment should be checked to ensure they
comply with the requirements of environmental protection legislation. In some cases,
fume scrubbers, filters or engineering modifications to the process equipment will be
necessary to reduce emissions to acceptable levels.
>100°C (>212°F)
Liquid.
Not available.
White.
Boiling/condensation point
Physical and chemical properties
Physical state
Odor
Color
:
:
:
:
Flash point :
Closed cup:None. [Setaflash. ASTM D3828]
9 .
4/9
8/13/2012.