User manual
12
© 2006, Elektro-Automatik GmbH & Co. KG
Irrtümer und Änderungen vorbehalten
EN
© 2009, Elektro-Automatik GmbH & Co. KG
About the device
General
Introduction
The microprocessor controlled power supplies of the
PS 800 R series are designed for wall mount and work
with a convectional cooling.
The functionality focuses industrial power supply. It
means, the device will continue its work with the last
settings after a blackout.
Models up to 65V output voltage feature two xed
voltages which are dedicated to load batteries with
12V, 24V or 48V (depending on the model). One of
the xed voltages is for normal charging, the other
for trickle charging. A third selectable voltage range
offers a trimmer to adjust the output voltage within
0...100% nominal value.
At models with 160V or higher, the output voltage
is seperated into three selectable ranges, where
each is dened as approximately 1/3 of the nominal
voltage.
The power output is short-circuit-proof and over-
load-proof. For protection of the loads, the devices
also feature an overvoltage protection (OVP). At an
overtemperature (OT) event, the power output will
be switched off until the unit has cooled down and
automatically switch on again.
Visual check
After receipt, the unit has to be checked for signs
of physical damage. If any damage is found, the
unit may not be operated. Also contact your dealer
immediately.
Replacing the internal fuse
The main fuse is located inside the device. Before
opening the device, completely disconnect it from
mains.
Working on the open device must only be done by
trained technical personnel which is instructed about
the dangers and safety regulations.
In order to replace the fuse, unscrew the front cover
plate and remove it precautiously. The fuse is located
on the main PCB, on the left-hand side.
Scope of delivery
1 x Power supply unit
1 x Printed user manual
1 x Mains connector
Installation
Mounting
The device is designed for wall mount. It is required
to mount it in a way that allows unimpeded air ow
through the ventilation slots. Take care for plenty of
space (at least 15cm) below and above the device in
order to ensure proper cooling.
Mains connection
All models are equipped with an active PFC (power
factor correction) and a wide range input. It can be
operated at AC input voltages from 90V to 264V and
mains frequencies of 45Hz up to 65Hz.
The connection is done with the included 3pole plug
(Phoenix Combicon GMSTB 2,5/3-ST-7,62) according
to the print on the front plate. It must only be carried
out by trained technical personnel. Main focus lies
on an appropriate cross section of the mains lead,
as well as the fact that the device does not feature a
power switch. The mains input is fused by a standard
5x20mm fuse which is located inside the unit.
Functional description
Remote sense
In order to compensate voltage drops along the load
leads, the device features remote sense inputs on
the front. Here the sensed voltage from the load is
connected with correct polarity. Remote sense can
compensate up to 2V.
When not using the sense inputs, they just remain
open. It is not required to bridge them to the output.
The cross section of the sense leads is non-critical.
Overvoltage protection (OVP)
All models feature an overvoltage protection circuit
which is set 110% of the nominal output voltage. In
case of an overvoltage condition, whether caused by
an internal defect or by external reasons, the power
output is switched off and the error is indicated by
the LED „OVP“ and also by pin 10 of the analogue
interface. After the OV condition is gone, the output
can be switched on again.
Overtemperature (OT)
All models also feature an internal temperature super-
vision. In case of overheating, the power output will
be temporarily switched off until the device has cooled
down, and then automatically switch on again.
The condition is indicated by the LED „OT“ and by pin
10 of the analogue interface.