User manual
31
© 2009, Elektro-Automatik GmbH & Co. KG
EN
Functional description
Minimum battery voltage required for charging
Precharge current (in C) (Example: Battery with 100Ah -> 1C = 100A)
Precharge end voltage
Precharge maximum time
Current threshold for change to trickle charge (in C)
Boost charge maximum time
Normal charge maximum time
Trickle charge voltage
Cell supervision on/off
Cell supervision threshold for charging stop
Temperature compensation for normal charge
Temperature compensation for trickle charge
Battery prole for lead batteries
Values in brackets dene the setting range
Battery prole for Lithium batteries
Values in brackets dene the setting range
Minimum battery voltage required for charging
Precharge current (inC) (Example: Battery with 100Ah -> 1C = 100A)
Precharge end voltage
Precharge maximum time
Charging current threshold for charging stop (in C)
Normal charge maximum time
Absolute temperature range for battery charging