User manual

34
© 2006, Elektro-Automatik GmbH & Co. KG
Irrtümer und Änderungen vorbehalten
EN
© 2009, Elektro-Automatik GmbH & Co. KG
Functional description
Display in Charger mode Display in Power Supply mode Code Bedeutung
Charger overvoltage OV 01 Overvoltage error
Charger overtemp. OT 02 Overtemperature error in the device
Charger system error SYS 03 System error
CAN communication error CAN 20 CAN communication error
Bat. temp out of range 37 Battery temperature too high
Bat. temp out of range 38 Battery temperature too low
Bat.voltage out of range Ub> 39 Battery voltage too high
Bat. deeply discharged
40
Battery voltage too low
Cell fault in battery
41 Cell short-circuited or defective
Temp.sensor fault 42 Temperature sensor missing or defective
Reverse polarity -Ub 43 Battery connect with reverse polarity
No battery detected 44 No battery connected (only in charger mode)
Some explanations about the list:
No battery detected is displayed in charger mode
as long as no battery is connected (battery voltage =
0V).
Bat. deeply discharged indicates that the connected
battery is either deeply discharged, defective or just of
wrong nominal voltage.
• if a battery is connected while the device is in Power
Supply mode, the battery voltage is supervised like
in Battery Charger mode and related errors are re-
ported.
The analogue interface
Technical specications
Pin Name
Type
1
Description Level Electrical specifications
1 Temp. sensor AI Temperature sensor Positive connector
2
Battery full DO Charging done / Trickle charge
Level is user-defineable in device setup
U
Low
<1V, U
High
>4V
3 Charging DO Charging active
Level is user-defineable in device setup
U
Low
<1V, U
High
>4V
4 VMON AO Actual value: voltage
0….10V corresponds to 0….100% of U
Nom
5 CMON AO Actual value: current
0….10V corresponds to 0….100% of I
Nom
6 AGND Reference for analogue signals For CMON, VMON, Temp.sensor
7 REMOTE DI Activate remote control
Level is user-defineable in device setup
U
Low
<1V, U
High
>4V
8
RUN /
REM-SB
DI
PS mode: Power output off
Bat mode: Run/Stop charging
Level is user-defineable in device setup
U
Low
<1V, U
High
>4V
9 ERROR DO
General error output
Level is user-defineable in device setup
U
Low
<1V, U
High
>4V
U
Max
= 30V, I
Max
= 20mA
Quasi open collector with
pull-up to Vcc
2
10 DGND Reference for digital signals For control and monitoring signals
11 CV DO Constant voltage operation
Level is user-defineable in device setup
U
Low
<1V, U
High
>4V
U
Max
= 30V, I
Max
= 20mA
Quasi open collector with
pull-up to Vcc
2
12 Vcc AO Auxiliary voltage 12….16V
I
Max =
24mA
Short-circuit-proof against DGND
1)
AO = Analogue output, DI = digital input, DO = digital output
2)
12V...15V
U
Max
= 30V, I
Max
= 20mA
Quasi open collector with
pull-up to Vcc 2
Accuracy 0.1% at I
Max
= +2mA
Short-circuit-proof against AGND
U
max
= 30V
I
Max
= -1mA at 5V