User manual

IVC Card Features and Support
Establish the OAI Channel
Use this two-stage procedure to build an Open Application Interface (OAI) channel
on a PointSpan switch. The switch requires an OAI channel to communicate with the
Phrase Manager application.
Stage Description
1
Build the OAI channel in the switch database
2
Verify the OAI channel
Build the OAI Channel in the Switch Database
Do the following:
Step Action Result
1. At the main Administrative Console
prompt, type UTIL.
The console displays:
SELECT COMMAND => UTIL
SELECT SUBCOMMAND or ? ... =>
2. Type ILK (Information Link). The console displays:
SELECT MODE: PRINT, DISPLAY,
UPDATE... =>
3. Type U. The console displays:
SELECT UPDATE: CREATE,
MODIFY, DELETE... =>
4. Type C. The console displays:
INFORMATION LINK DEVICE TYPE
or ?... =>
5. Type OAIx-s, where x is the correct
OAI channel. For example, enter
OAI3-s for OAI channel 3.
The console displays:
ENTER TITLE:...________ =>
6. Type an appropriate title for the OAI
channel, such as "OAI Channel 3."
The console displays:
CTI/API NUMBER:...A.1 =>
7. Type A1. The console displays:
INET ADDRESS: or ?... =>
8. Type the IP address for the Phrase
Manager PC.
The console displays:
PORT NUMBER OF
ALLOCATION:... =>
9. Type 8160. The console displays the parameters of
the OAI channel followed by:
DOES UPDATE VERIFY ? =>
M
M
Aastra - 2489-005 31