User manual
IVC Card Features and Support
Parameter Function
IVS Group Assigns an IVS group, by number. The system uses
an IVC device associated with this IVS group to collect
DTMF digits.
Allowable Parameter Types
Fixed value, user-defined constant
Wait Time for IVS Device Defines the duration that the system waits for an IVC
device to become available. Valid values include:
Value Meaning
1-255 The duration of the wait,
in seconds.
0 The system will not wait
for an available device;
it immediately proceeds
to the call guide step
when no IVC group is
available.
-1 Indicates "no timing;" the
system waits indefinitely
for an IVC device to be
available.
Allowable Parameter Types
Fixed value, pre-defined constant, user-defined
constant, user-defined variable, system variable,
pre-defined function
Unavailable IVS Device Step Defines a call guide step to which the system will
proceed if no IVC device becomes available within the
wait time. This parameter can specify either a step
number, a step label, or "Next." Next instructs the
system to execute the call guide step that immediately
follows the End Get Digits step.
Allowable Parameter Types
Fixed value, pre-defined constant, user-defined
constant, user-defined variable, system variable,
pre-defined function, label.
M
M
Aastra - 2489-005 49