User manual

Chapter 7, Call Guide and Digit Collection Template
Digit Collection Parameter Description
Digit Validation Specifies one of the following methods to validate
the caller input.
Method Description
Digit Validates each digit individually,
one-by-one. A Valid Digits for
Digit N
parameter defines the
valid values for each digit based
on its place (N) in the digit string.
Range Validates an integer value against
a defined range. The Minimum
Numeric Value and Maximum
Numeric Value parameters set
the valid range for the integer.
None Does not validate caller digits.
The Range method is only available for integers.
First Digit Wait Time Defines the maximum time that the system will wait
for the first input digit before advancing to the next
step in a call guide. Valid values include:
0 to 60 seconds
N, which specifies the wait time as the value
of the Normal Inter-digit Time (NIT) user group
parameter.
F, which specifies the wait time as the value
of the Fast Inter-digit Time (NIT) user group
parameter.
Interdigit Wait Time Defines the maximum time that the system will
wait for each input digit after the first before
advancing to the next step in a call guide. Valid
values include:
0 to 60 seconds
N, which specifies the wait time as the value
of the Normal Inter-digit Time (NIT) user group
parameter.
F, which specifies the wait time as the value
of the Fast Inter-digit Time (NIT) user group
parameter.
M
M
60 Aastra – 2489-005