Eagle Instruction Manual Setup Mode 29
Updating the display increment setting
1. Press the SHIFT/ button to place the prompt in the third line,
then press the POWER/ENTER button. The display increment
setting flashes. The allowable settings are 0.2 VOL% (default) and
0.5 VOL%.
2. Press the AIR/ or SHIFT/ button to display the desired
display increment setting, then press the POWER/ENTER button
to enter the setting. The prompt flashes.
Returning to the main menu
1. Press the SHIFT/ button. The ESCAPE message displays. (Press
the AIR/ button to return to the previous screen.)
2. Press the POWER/ENTER button to save the new settings. The
OTHER GAS SET message displays, then the Gas Combinations
menu displays.
3. To exit the Gas Combinations menu, press the SHIFT/ button
until the prompt is next to Channel 4, then press the SHIFT/
button again. The ESCAPE message displays.
4. Press the POWER/ENTER button. The message SAVING DATA
displays, then the main menu displays.
Updating toxics channel settings
This section describes how to update the target gas label, set a custom
gas label, and update the fullscale and display increment settings for a
toxic gas channel.
Updating the target gas label
1. From the main menu, select the GAS COMBINATIONS menu
option.
2. Press the POWER/ENTER button to display the Gas
Combinations menu.
3. Use the AIR/ or SHIFT/ button to place the prompt next to
the toxic gas channel (in this example H2S or CO).
4. Press the POWER/ENTER button. The toxic target gas label
flashes. This indicates that this setting can now be updated.