DCS302 DUAL CYLINDER SCALE INSTALLATION & OPERATION MANUAL Eagle Microsystems, Inc. 366 Circle of Progress Pottstown, PA 19464 www.eaglemicrosystems.
DCS302 GENERAL INFORMATION GENERAL The DCS302 is a dual cylinder scale designed specifically for the water and wastewater industry. The scale base and weighing surfaces are made of Type 2 PVC plastic and are guaranteed for five years against environmental damage. All mechanical parts, wherever possible, are made of stainless steel or protected with a durable chemical-resistant powder finish. The DCS302 can accommodate any cylinder that does not exceed 12” diameter and 150 lbs. net weight.
INSTRUCTIONS DCS302 DUAL CYLINDER LOAD CELL SCALE 1. Before placing scale in operation remove the six (6) plastic stops and the aluminum shipping plate located on the underside of the scale. 2. Determine service location of scale and position base 2 1/2-inches or more from the wall. 3. Anchor scale base securely to smooth, level floor using 3/8-inch anchor bolts (not supplied) through the four (4) 1/2-inch diameter holes in the corners of the scale base.
SCALE INSTALLATION CHLORINE CL 30" RECOMMENDED ELEVATION 40" 1 5/8" 5 5/8" MINIMUM WALL CLEARANCE WALL 2 1/2" DCS302 FOOT PRINT 16" 16" 18" 30" 30" 31 1/2" 1/2" CLR. HOLE 4 PLCS. 15FT.
EI2000 INDICATOR 5 5/8" ctr. to ctr. mounting holes Wall Mounting Dimensions EI-2000 5 3/8" ctr. to ctr.
CHLORINE EI-2000 ZERO AC ZERO SELECT 15' CABLE NEUTRAL HOT GROUND AC Power P1 LEFT RIGHT RIGHT LEFT Alarm Contacts P2 H J2 + 4 3 R + T1 CH1 CH2 RELAYS L 8 7 J3 CH1 CH2 C20 U6 J4 J2 ALARM RELAY OPTION J6 SERIAL PORT OPTION J3 4-20 mA ANALOG OUTPUT J5 RIGHT SCALE INPUT PIN G N H +E +S –S –E SH +E +S -S –E SH L+ L– R+ R– L R A B G R T CH2 RIGHT SCALE + +E +S –S –E SH A B C RS485 R LEFT POS.
TEST PROCEDURES DCS302 DUAL CYLINDER LOAD CELL SCALE 1. After assembly a known weight of 250 lbs. is alternately placed on each platform and removed two times in order to flex the components of the scale base. 2. Upon loading the scale for the third time, the display of the EI-2000 indicator allowed to stabilize. The display value is noted and, in Mode 3 Automatic Operation, the display is adjusted to read the known weight using the Up/Down arrow keys.
DCS302 DUAL CYLINDER SCALE BASE 14 SPIDER DRAWING 48 49 (Not Shown) 13 15 12 10 1 9 2 8 7 3 4 5 6
44 37 37 DMS/DCS SPIDER ASSEMBLY 45 38 BASE 39 43 13 40 44 36 DISK 41 41 41 46 37 42 38 SPIDER DRAWING
DRAWING KEY ITEM DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16-35 36 37 38 39 40 41 42 43 44 45 46 47 Locknut Adjusting bolt, ss Pin, spring (split), ss, type 420 Chain, sash, ss, 1/0 Chain clip Enclosure, FG 5x5x3 Bracket, cell, PVC-1 Load cell, 40#, 14”, 350 ohm Term. block, 6 ckt, screw term.