HOSPITAL VAC MODELS: S6101HQ-T S6101HQ-S OPERATIONS AND PARTS MANUAL IMPORTANT! READ THIS MANUAL PRIOR TO USE
TABLE OF CONTENTS Important Safety Instructions ..................................................... 1 Operation ................................................................................... 4 Assembly Instructions ............................................................... 5 Maintenance ............................................................................... 6 Servicing the Vac Motor ............................................................. 7 Part Diagrams ............................
IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. WARNING DANGER: Failure to read and observe all DANGER statements could result in severe bodily injury or death. Read and observe all DANGER statements found in your Owner’s Manual and on your machine.
WARNING: Operating a machine without observing all labels, decals, etc., could result in injury or damage. Read all machine labels before attempting to operate the machine. Make sure all of the labels are attached or fastened to the machine. Get replacement labels and decals from the manufacturer’s distributor. WARNING: Use of this machine to move other objects or to climb on could result in injury to the operator or damage to the machine. Do not use this machine as a step or furniture.
Page 3
SET UP AND OPERATION WARNING: THE UNIT IS FOR DRY VACUUMING ONLY AND MUST BE STORED IN A DRY LOCATION 1. Attach paper bag to tank inlet deflector. See Figure 1. 2. Ensure that the cartridge filter is securely attached to the bottom of the vacuum head. See Figure 2. For S6101HQ-T units, insert basket filter into the tank. See Figure 2-A. Figure 1 3. Place vacuum head onto the tank and secure it with the two clamps. 4. Insert hose into the tank inlet until it locks in. See Figure 3. Figure 2 5.
POWER HEAD AND WAND ASSEMBLY INSTRUCTIONS Locking Collars 1. Slide on the two collars as pictured. See Figure 1 2. Insert wand into the power head neck until it stops. Slide the small collar into the neck of the power head. Screw the large collar onto the powerhead until tight. See Figure 2 3. Firmly press the two wands together. 4. Firmly press upper bent wand into the straight wand. Figure 1 5. Attach two cord hangers to wand and cord. See Figure 3 6. Evenly attach 3 cord hangers to the hose and cord.
SERVICING THE FILTER The filter is accessed by lifting the head assembly off the tank. Cartridge filters - Remove the filter retainer by turning the black knob 90 degrees counter-clockwise. Cartridge filter will then slide off. NOTE: Be sure to frequently clean the filter Worn filters can affect vacuum performance. Replace the filter when it becomes worn out and norman cleaning will not restore vac performance. PERIODIC MAINTENANCE (Every six to twelve months): 1.
SERVICING THE VAC MOTOR CARBON BRUSH REPLACEMENT (Replacement Carbon Brushes: Part #S8053200) 1. Disconnect power cord from power source. 2. To access the vac motor, remove the screws that attach the main cover to the head assembly and set the cover to one side. 3. Remove the screws that attach the inner cover to the head assembly and set aside. 4. Remove the carbon brush assembly by removing the 2 screws that attach it to the vac motor. See Figure 1 5.
VACUUM MOTOR ASSEMBLY (S6101 HQ-S) POS.
VACUUM MOTOR ASSEMBLY (S6101 HQ-T) POS.
TANK AND CART ASSEMBLY (S6101HQ-T) POS. PART # DESCRIPTION QTY 1 2 3 4 5 6 7 8 S82652A S82846 S82593 S82585 S86132G5-NE S81026 S81302 S83602 INLET COVER GASKET DEFLECTOR, TANK RETAINER, TANK ADAPTOR TANK SCREW, (PHILLIPS) M5 X 30 RIVET, M5 X 19 CLAMP, TANK, COMPLETE 1 1 1 1 1 4 4 2 POS.
TANK AND CART ASSEMBLY (S6101 HQ-S) POS. PART # DESCRIPTION QTY 1 2 3 4 5 6 7 8 S82652A S82846 S82593 S82585 S86039G55-GP S81026 S81302 S83602 INLET COVER GASKET DEFLECTOR, TANK RETAINER, TANK ADAPTOR TANK SCREW, (PHILLIPS) M5 X 30 RIVET, M5 X 19 CLAMP, TANK, COMPLETE 1 1 1 1 1 4 4 2 POS.
POWER HEAD ASSEMBLY POS.
TOOLS A G C F D B E POS.
Warranty Policy Limited Warranty Eagle Power Products (EPP) warrants new cleaning equipment against defects in material and workmanship under normal use and service to the original purchaser as detailed below. 10 Years Subject to the conditions stated below, EPP warrants polyethylene tanks and housings to be free from defects in materials and workmanship for a period of ten years.