Sliding Gate Eagle-2000 Series Eagle-1000 Series ntrol Systems, Inc. (800)708-8848 www.eagleoperators.com Operator installation and instructions for the Eagle-2000 and Eagle-1000 Series.
Table of Contents Contents: Page(s): UL Listings Installing the Warning Sign / Precautions Instructions on Gate Posts Positive Stops Methods of Installation Proper Chain Installation Mounting Operator(s) to Concrete Pads Selecting the Opening Direction of Gate Connecting the Power Reverse / Exit Loop Installations Two Way Adjustable Reverse Sensors / ERD The Feature Selector Master and Slave Operation Master Control Slave Control Selecting the Delay Functions Describing the Output Connections MAG Lock Sol
UL Listings Gate Operators Installation Instructions 1) Install the gate operator only when: The operator is appropriate for the construction and the usage Class of the gate. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to prevent a 2 ΒΌ inch (57.15 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.
UL Listings Essential Safety Procedures WARNING - TO REDUCE THE RISK OF INJURY OR DEATH - READ AND FOLLOW ALL INSTRUCTIONS: Never let children operate or play with gate controls. Keep the remote control away from children. Always keep people and objects away from gate while the gate is in operation. NO ONE SHOULD CROSS THE PATH OF A MOVING GATE. Test the gate operator monthly. The gate must reverse on contact with a rigid object or stop when an object activates the non-contact sensors.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Installing the Warning Sign Install Warning Sign On Both Sides Of Gate ____________________ Precautions ! Be sure to mount ALL operating devices clearly out of reach of through gate. ! ____________________ Regarding Ornamental Grill Styled Gates: Injuries may be avoided if a mesh or screen is installed on the gate.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Instructions on Gate Posts Important Notice! Because the coasting distance may vary due to change in temperature, Eagle Access Controls does NOT recommend the installation of a stop or catch post in front of the gate path as shown in Example A. To do so will cause the gate to hit the post in certain instances.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Methods of Installation CAUTION! ! It is highly recommended to install "over travel stops" at both ends of the gate rail in any type of installation in order to prevent derailing. Front Installation * * * Recommended Positive Stop Locations Rear Installation * ____________________ * Proper Chain Installation Minimum space between gate and output sprocket must be 4".
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Mounting Operator(s) To A Concrete Pad CAUTION! ! Be sure that the operator is installed in a level and paralleled position and is properly secured. Improper installation could result in property damage, severe injury, and/or death. Note: The following concrete recommendations are installation suggestions only. Please consult local codes for actual requirements in your area.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Connecting The Power CAUTION! ! Be sure that the circuit breaker for the line input power is turned off before connecting the input power to the unit. Connect 120 VAC, 15A, 60HZ, line input power to the wires provided in the power switch junction box located near the bottom of the operator. Warning: Eagle Access Control Systems, Inc is not responsible for researching and complying with local building codes.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Two Way Adjustable Reverse Sensor / ERD CAUTION! ! Only a qualified service technician must make all adjustments to the senso The Eagle Diamond Control Board has two separate pots for adjusting sensitivity. One is for opening the gate, and the other is for closing the gate. IMPORTANT The level of sensitivity has to do with the weight of the gate and the conditions of the installation.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ The Feature Selector The selector uses an eight-station switch system that allows selection of the standard features and customized installation settings. The switch description is as follows: Note: The power should always be turned off when designating feature selector switches Diamond Board FEATURE SELECTOR Switch 1: Slave/Master - Sets the operator to work as Master or Slave.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ The Feature Selector (Continued) Switch 4: Reverse Loop - Sets the reverse loop to be normally open or to normally close. It is useful in Fail-Safe applications. Switch 5: One Pass (On/Off) - This tailgating feature works with the reverse loop to allow only one car to pass. After the car passes, the gate closes instantly. If a second car approaches the gate stops. The operator resumes closing after the car leaves.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Master and Slave Operation Important: Be sure that the 120VAC power (for the Master and the Slave) are connected to the same circuit breaker. Use 20GA stranded wire for Master/Slave communication Master Diamond Board Slave Diamond Board NOTE: The polarity is very important when connecting Master / Slave Operations.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Slave Control Options Switch #1 must be set to the Slave or to the "off" position. Switch #2 must be set to the "open left" or to the "open right" position. Switch #3 brake on / off. Switch #4 Not in use.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Describing The Output Connections Entire Output Section MAG Lock Solenoid Connections (24 VDC) The Eagle Diamond Control Board provides a 24VDC and relay output for MAG Locks or Solenoids. Alarm (12 VDC) Safety Alarm: If the gate hits an obstruction twice while closing or opening, the system will shut down for 5 minutes. On the Diamond Board, you have two options of reset mode.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Connecting The Accessories With the exeption of the MAG Lock, all of these accessories can be installed on the Master or Slave operator. Reverse Loop Key Lock Box Fire Lock Box Phantom Loop MAG Lock Exit Loop Phone Entry System Open Edge Sensor Close Stop Three Button Push Station Eagle Access Control Systems, Inc. / (800) 708-8848 / www.eagleoperators.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Description of Inputs 1. Reverse Loop - Momentary or Continuous Signal This input is active only when the gate is closing or when its fully open. If this input is active, the close timer is disabled. All vehicle detectors and photo-eyes should be connected here. Multiple devices may be connected in parallel. 2.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Receiver Connections The receiver terminal is mounted on the control box for easy installation and is pre-wired for a 3-wire or 4-wire receiver. 4-Wire Connections 3-Wire Connections When installing 4-wire, use terminals 1 & 2.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Emergency Releases The Fail Secure System Release Instructions: ! (1) Turn off the power - Failure to do so can result in serious injury or death.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Mounting The Secondary Entrapment Note: Eagle Access Control Systems, Inc. recommends the installation of Edge Sensors on all sliding gate operator systems. All Contact Sensors Are Connected To Edge Sensor Inputs * EDGE SENSORS WALL * WALL (TOP VIEW) * * * * GATE OPENING Eagle Operator * All Edge Sensors are shown at recommended locations.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Control Board LED Indicators 17 10 9 1. Power On 2. Master / Slave Communication 3. Edge Sensor 4. Close 8 7 6 16 5 5. Key / Keypad 6. Stop 7. Exit / Open 8. Phantom Loop 9. Reverse Loop 14 15 4 3 10. Receiver 11. Close Limit 12. Closing 13. Opening 14. Open Limit 13 1 12 11 2 15. Overload 16. Active 17. Timer Eagle Access Control Systems, Inc. / (800) 708-8848 / www.eagleoperators.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Troubleshooting SYMPTOMS PROBABLE CAUSES REMEDY Gate stops and reverses direction in mid travel and the OVERLOAD LED remains ON. (A) Gate operator is not plumb and level. (B) ERD current sense may be set to sensitive. (C) Gate encountered an obstruction while in travel. (D) The Gate's V-Groove wheels are worn. (A) Remount operator or chain brackets. (B) Turn the ERD sensor slightly in the clockwise direction.
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Parts Breakdown / Eagle-2000 Entire Kit - E300 No Weld Chain Assembly E307 E305 E555 E293 E306 E525 E333 E292 Entire Assembly Kit E106 E194 LIMIT SWITCH ASSEMBLY E132 E107 E135 E108 E109 E100 E098 E110 E099 E136 E168 E242 Limit Switches E185 E097 E181 E144 Model-2000-FSF E166 E032 E266 Model-2000 Entire Kit - E301 Fail Secure System E167 FSF Model-2000 E255 E031 FSC E277 E256 E257 Entire FSC Syste
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Parts Breakdown / Eagle-1000 E525 E555 E293 E444 E292 Entire Assembly Kit E106 LIMIT SWITCH ASSEMBLY E198 E132 Entire Kit - E300 E107 No Weld Chain Assembly E108 E109 E133 E307 E305 E100 E098 E110 E099 E306 E169 E241 Limit Switches E281 E185 E097 E145 Model-1000-FSF E265 E267 E266 Model-1000 Entire Kit - E301 Fail Secure System E022 Model-1000 FSF FSC E278 E255 E256 E257 E285 - FSC E286 - FSF Eag
Slide Gate Operators / Eagle-2000 Series / Eagle-1000 Series ____________________ Operator Parts List Eagle-2000 Slide Operator Eagle-1000 Slide Operator E333 - Operator Cover E293 - Plastic (Control Board Box) Cover E292 - Control Board Box E555 - Diamond Control Board E194 - Eagle-2000 Chassis E106 - Limit Switch (LS) Assembly (Complete) E444 - Operator Cover E293 - Plastic (Control Board Box) Cover E292 - Control Board Box E555 - Diamond Control Board E198 - Eagle-1000 Chassis E106 - Limit Switch (LS
Eagle Access Control Systems, Inc. Eagle Access Control Systems, Inc. designs its gate operators with the dealer/installer in mind, constructing all Eagle operators to be easy to install and to service. From our very first operator, the Eagle-2000, with its superb features and easy to install construction, to the full range of commercial and residential sliding and swing gate operators we now offer, Eagle Access has always provided what our customers need.