PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Compressor operating out- Provide adequate protec-
side in cold conditions or inlet tion against extreme weather
filter not protected against conditions.
weather
Worn piston rings Replace piston rings
Piston rings not seated See below.
Piston rings Allow 100 hours of normal op-
not seated eration for new rings to seat.
Drain oil and refill with Eagle
EAOIL oil or other approved oils