Technical data
Actuator with low level switching element
Switching system
This low level switching element was designed for switching low
powers in electronic circuits. The mechanism assures reliable
switching of loads ranging from a few μA / μV up to 100 mA /
42 VAC/DC.
Single-break momentary contact, as normally open or normally
closed with 4 independent points of contact. 2 momentary con-
tacts per switching element; combination of normally open and
normally closed is possible.
Special features are the long life, extremely short rebound time
and stable contact resistance.
Material
Material of contact
Gold plated
Switch housing
Polysulfone (PSU), heat-resistant and self-extinguishing
Actuator housing
Polyphenylene (PPO), self-extinguishing
Mechanical characteristics
Terminals
The universal terminals permit these units to be mounted on
printed circuit boards (PCB). These terminals can also be used as
soldering or plug-in terminals.
For these terminals we can also supply a plug-in base which,
when soldered on to the board, enables the switch to be plugged
in.
Soldering terminal:
Max. wire diameter 2 wires à 0.8 mm
Max. wire cross-section of stranded cable 1x 0.75 mm²
Plug-in terminal: 2.0 x 0.5 mm
Actuating force
3 N ... 3,5 N
Actuating travel
3 mm
Rebound time
Typ. <100 μs
Mechanical lifetime
Momentary action 5 million cycles of operation
Maintained action 1 million cycles of operation
Electrical characteristics
Standards
EN 61058
Contact resistance
Starting value (initial) ≤50 mΩ
Switch rating
10 μA, 100 μV to 100 mA at 42 VAC/VDC
Electric strength
2500 VAC, 50 Hz, 1 min. between all terminals and earth, as per
IEC 60512-2-11
Protection class
II
Environmental conditions
Storage temperature
-40 °C ... +85 °C
Service temperature
-25 °C ... +55 °C
For indicators and illuminated pushbuttons mounted as a block,
make sure the heat can escape freely.
Protection degree
Front P 40
IP 67 with front protective cap
Shock resistance
(Single impacts, semi-sinusoidal)
15 g for 11 ms, as per IEC 60512-4-3, IEC 60068-2-27
Climate resistance
Standard condition, as per IEC 60068-2-3 and 2-30
Changing condition, as per IEC 60068-2-14 and 2-33
EAO reserves the right to alter specications without further
notice.
Approvals
Approbations
CB (IEC 61058)
CSA
ENEC (EN 61058)
Germanischer Lloyd
UL
Declaration of conformity
CE
01