Datasheet

Technical data
Indicator actuator
Material
Actuator element
Plastic
Front ring
Plastic or metal
Actuator housing
Plastic or metal
Ambient conditions
Operating temperature
25 °C … + 70 °C
Storage temperature
40 °C … + 80 °C
Protection degree
IP66, IP67, IP69K
Vibration resistance
According to IEC 60068-2-6
2 … 500 Hz: 5 g
Shock resistance
According to IEC 60068-2-27
Sinusoidal half-wave 50 g / 11 ms
Climatic ambient conditions
During operation according to IEC 60721:
3K6, 3C3, 3S2, 3M6
Duo Indicator
Material
Actuator element
Plastic
Front ring
Plastic or metal
Actuator housing
Plastic or metal
Mechanical characteristics
Terminal
Screw terminal
- Solid without end sleeves 2 x (1.0 … 1.5
mm
2
)
- Solid with end sleeves 2 x (0.5 … 0.75
mm
2
)
- Finely stranded without end sleeves 2 x (0.5 … 0.75
mm
2
)
- Finely stranded with end sleeves 2 x (0.5 … 1.5
mm
2
)
- For AWG cables for auxiliary contacts 2 x (18 … 14)
Tightening torque
Screw terminal 0.8 … 1 Nm
Electrical characteristics
Insulation voltage
Rated value 320
V
Pollution degree
3
Surge voltage resistance
Rated value 4 kV
Operating voltage
at AC/DC
- Rated value 6 … 24 V
at AC
- Rated value 110 or 230 V
Ambient conditions
Operating temperature
25 °C … + 70 °C
Storage temperature
40 °C … + 80 °C
Protection degree
IP66, IP67, IP69K
Vibration resistance
According to IEC 60068-2-6
10 … 500 Hz: 5 g
Shock resistance
According to IEC 60068-2-27
Sinusoidal half-wave 50 g / 11 ms
Climatic ambient conditions
During operation according to IEC 60721:
3B2, 3K6, 3S2, 3M6