Datasheet

Technical data
Slow-make switching element
Switching system
The double-break, slow-make switching element is equipped with
one or two independent contact systems, acting as normally open
or normally closed contact. The normally closed contact has
forced opening.
Slow-make contacts with forced action are ideal for high switch
ratings.
Up to three switching elements can be snapped to each actuator.
For the emergency-stop pushbutton use the slow-make switching
element (max. 2).
Material
Material of contact
Hard silver, gold-silver, silver-palladium (for aggressive atmospheres)
Switch housing
Plastic
Mechanical characteristics
Terminals
Screw terminals
Plug-in terminals 6.3
mm x 0.8 mm
Max. wire cross-section 2 x 2.5
mm²
Max. wire cross-section of stranded cable 2 x 1.5
mm²
For switches with plug-in terminals it is necessary to provide
insulation sleeves and to maintain a spacing of 65
mm between
rows (mounting cut-outs)
Tightening torque
Screws at the plastic mounting ange max. 0.4
0.5 Nm
Screws at the metal mounting ange max. 0.25
0.3 Nm
Screws at switching element max. 0.50
Nm
Actuating force
1 Normally closed 2
N
1 Normally open 3.1
N
Actuating travel
Approx. 5.8
mm ± 0.2 mm
Mechanical lifetime
(with 1 switching element)
Pushbutton maintained action
1.5 million cycles of operation
Pushbutton momentary action
3 million cycles of operation
Selector switch maintained action
1.25 million cycles of operation
Selector switch momentary action
2.5 million cycles of operation
Emergency-stop switch
50 000 cycles of operation
Keylock switch maintained action
25 000 cycles of operation
Keylock switch momentary action
50 000 cycles of operation
Electrical characteristics
Standards
The switches comply with the “Standards for low-voltage
switching
devices” DIN EN 60947-5-1
Rated Insulation Voltage U
i
500 VAC/600 VDC, as per DIN EN 60947-5-1
Electrical life
50 000 cycles of operations
Thermal current I
th
10 A
Switching voltage and switching current
as per EN IEC 60947-5-1
AC-15: 230 V, 7 A AC-15: 400 V, 5 A
AC-15: 500 V, 4 A DC-13: 24 V, 10 A
DC-13: 60 V, 5 A DC-13: 110 V, 2.5 A
Recommended minimum operational data
Gold-silver contacts:
Voltage 24 VDC 110 VDC
Current 5 mA 2 mA
Hard silver contacts:
Voltage 24 VDC 110 VDC
Current 50 mA 10 mA
Protection class
Indicators and switches, t for mounting into devices with protec-
tion class II
Ambient conditions
Storage temperature
40 °C + 85 °C
Operating temperature
40 °C + 55 °C
(other temperatures on request)
Protection degree
IP00
Shock resistance
(single impacts, semi-sinusoidal)
300 m / s² pulse width 11 ms, as per EN IEC 60068-2-27
Vibration resistance
(sinusoidal)
100 m / s² at 10 Hz 500 Hz, amplitude 0.75 mm, as per
EN IEC 60068-2-6
eao.com § 07/2019
246
04
01
02
03
04
09
14
17
18
19
22
31
41
45
51
56
57
61
70
71
82
84
92
96