Series Series 82 Robust and attractive. https://eao.
82 Information about the Series Key advantages § § § § § § § § Vandal-resistant: Impact resistant to IK10 Front protection up to IP67 Gold-plated silver contacts available for low voltages and currents Optional illumination and laser markings Excellent tactile feedback Long service life: > 1 million cycles of operation Stainless steel anodised aluminium or brass coloured switches 16 mm, 19 mm or 22 mm mounting Raitings § § § 24 VAC / DC (0.
Content 82 Flush design Pushbutton Ø 19 mm silver contact 4 Pushbutton Ø 19 mm gold-plated silver contact 6 Illuminated pushbutton Ø 19 mm silver contact 8 Illuminated pushbutton Ø 19 mm gold-plated silver contact 10 Illuminated pushbutton Ø 22 mm silver contact 12 Illuminated pushbutton Ø 22 mm gold-plated silver contact 14 Illuminated pushbutton Ø 22 mm stainless steel 316L 16 Indicator 19 mm 18 Indicator 22 mm 20 Accessories 22 Technical data 25 Marking 27 Order examples 28 Ap
82 Flush design Pushbutton Ø 19 mm silver contact, IP65, IP67 01 Equipment consisting of (schematic overview) 02 Ø 22 03 04 09 A 2 Product can differ from the current configuration. 14 M19x1mm 8 max. 33.5 max. Actuator B 37.5 max. Dimensions [mm] A = Solder terminal B = Screw terminal Fixing nut Each Part Number listed below includes all the black components shown in the 3D-drawing.
Flush design 82 Wiring diagrams 01 NC NO NC NO 02 03 c c 04 Wiring diagram 338 Wiring diagram 339 09 Component layouts 14 NC NC 17 + NO - C C NO 18 19 Component layout 84 Component layout 88 22 31 41 45 51 Follow us. We are on LinkedIn! 56 EAO creates possibilities. Since 1947. 57 61 70 71 Come take a look at our LinkedIn profi le today! Be sure to give us a follow so that you can fully interact with us. 82 https://www.linkedin.com/company/eao/ 84 92 96 www.eao.
82 Flush design Pushbutton Ø 19 mm gold-plated silver contact, IP65, IP67 01 Equipment consisting of (schematic overview) 02 Ø 22 03 04 09 A 2 Product can differ from the current configuration. 14 M19x1mm 8 max. 33.5 max. Actuator B 37.5 max. Dimensions [mm] A = Solder terminal B = Screw terminal Fixing nut Each Part Number listed below includes all the black components shown in the 3D-drawing.
Flush design 82 Wiring diagrams 01 NC NO NC NO 02 03 c c 04 Wiring diagram 338 Wiring diagram 339 09 Component layouts 14 NC NC 17 + NO C - C NO 18 19 Component layout 84 Component layout 88 22 31 41 45 51 56 57 61 70 71 82 84 92 96 09/2019 § eao.
2 Flush design Illuminated pushbutton Ø 19 mm silver contact, IP65, IP67 01 Equipment consisting of (schematic overview) 02 Ø 22 03 04 09 A 33.5 max. 2 Product can differ from the current configuration. 14 M19x1mm 8 max. Actuator B 37.5 max. Seal Dimensions [mm] A = Solder terminal B = Screw terminal Fixing nut Each Part Number listed below includes all the black components shown in the 3D-drawing.
Flush design Part No. Wiring diagram Component Layout 24 V DC 82-5152.22A4 342 87 24 V DC 82-5152.21A4 342 87 240 V 24 V DC 82-5152.12A4 343 87 Ring 240 V 24 V DC 82-5152.11A4 343 87 Dot 240 V 24 V DC 82-5151.22A4 342 85 Soldering terminal Ring 240 V 24 V DC 82-5151.21A4 342 85 flush Soldering terminal Dot 240 V 24 V DC 82-5151.12A4 343 85 flush Soldering terminal Ring 240 V 24 V DC 82-5151.
82 Flush design Illuminated pushbutton Ø 19 mm gold-plated silver contact, IP65, IP67 Equipment consisting of (schematic overview) 02 8 max. Ø 22 03 04 09 A 33.5 max. 2 Product can differ from the current configuration. 14 M19x1mm 01 Actuator B 37.5 max. Seal Dimensions [mm] A = Solder terminal B = Screw terminal Fixing nut Each Part Number listed below includes all the black components shown in the 3D-drawing.
Flush design Part No. Wiring diagram Component Layout 24 V DC 82-5154.21A4 342 87 24 V DC 82-5154.12A4 343 87 24 V 24 V DC 82-5154.11A4 343 87 Dot 24 V 24 V DC 82-5153.22A4 342 85 Soldering terminal Ring 24 V 24 V DC 82-5153.21A4 342 85 flush Soldering terminal Dot 24 V 24 V DC 82-5153.12A4 343 85 flush Soldering terminal Ring 24 V 24 V DC 82-5153.
82 Flush design Illuminated pushbutton Ø 22 mm silver contact, IP65, IP67 Equipment consisting of (schematic overview) 02 8 max. Ø 25 03 04 09 A 33.5 max. 2 Product can differ from the current configuration. M22x1mm 01 37.5 max. Seal Dimensions [mm] A = Solder terminal B = Screw terminal 14 Fixing nut Each Part Number listed below includes all the black components shown in the 3D-drawing.
Flush design 82 Component layouts - NC NO 01 NC + - C C 02 + NO 03 04 Component layout 85 Component layout 87 09 14 17 18 19 22 31 41 45 51 56 57 61 Robust and attractive. The optimised Series 82. 70 71 Now with gold-plated silver contacts for low-level applications available. . Impact resistant to IK10 . Front protection IP67 . Low-level applications possible . Optional illumination and laser marking . Excellent tactile feedback . Long service life 82 84 92 96 www.eao.
82 Flush design Illuminated pushbutton Ø 22 mm gold-plated silver contact, IP65, IP67 Equipment consisting of (schematic overview) 02 8 max. Ø 25 03 04 09 A 33.5 max. 2 Product can differ from the current configuration. M22x1mm 01 Actuator B 37.5 max. Seal Dimensions [mm] A = Solder terminal B = Screw terminal 14 Fixing nut Each Part Number listed below includes all the black components shown in the 3D-drawing.
Flush design 82 Component layouts - NC NO 01 NC + C - C 02 + NO 03 04 Component layout 85 Component layout 87 09 14 17 18 19 22 31 41 45 51 56 57 61 70 71 82 84 92 96 09/2019 § eao.
82 Flush design Illuminated pushbutton Ø 22 mm stainless steel 316L, IP65, IP67 Equipment consisting of (schematic overview) 02 8 max. Ø 25 03 04 09 A General information 17 • The laser 2D-technology can mark all stainless steel versions with flat lenses - flush-mounting as well as raised versions. Seal Dimensions [mm] Fixing nut Each Part Number listed below includes all the black components shown in the 3D-drawing. 31 min. 31 min. 14 Actuator 33.5 max.
Flush design 82 Wiring diagrams 01 NC NO NC NO NC NO + NC NO + 02 03 c c c – c – 04 Wiring diagram 338 Wiring diagram 339 Wiring diagram 340 Wiring diagram 341 09 Component layouts NC 14 - NO C NC NO 17 + C 18 19 Component layout 84 Component layout 85 22 31 41 45 51 EAO Downloads. www.eao.com/downloads 56 EAO creates possibilities. Since 1947. 57 61 70 71 On our website you can download technical data, assembly instructions, catalogs, brochures and much more.
82 Flush design Indicator 19 mm, IP65, IP67 Equipment consisting of (schematic overview) 02 8 max. Ø 22 03 04 09 A 2 Product can differ from the current configuration. 14 M19x1mm 01 33.5 max. Actuator B 37.5 max. Dimensions [mm] A = Solder terminal B = Screw terminal Fixing nut Each Part Number listed below includes all the black components shown in the 3D-drawing.
Flush design 82 Component layouts - 01 NC + - C 02 + NO 03 04 Component layout 86 Component layout 89 09 14 17 18 19 22 31 41 45 51 56 57 61 70 71 82 84 92 96 09/2019 § eao.
82 Flush design Indicator 22 mm, IP65, IP67 Equipment consisting of (schematic overview) 02 8 max. Ø 25 03 04 09 A 2 Product can differ from the current configuration. 14 M22x1mm 01 33.5 max. Actuator B 37.5 max. Dimensions [mm] A = Solder terminal B = Screw terminal Fixing nut Each Part Number listed below includes all the black components shown in the 3D-drawing.
Flush design 82 Component layouts - 01 NC + - C 02 + NO 03 04 Component layout 86 Component layout 89 09 14 17 18 19 22 31 41 45 51 56 57 61 70 71 82 84 92 96 09/2019 § eao.
82 Accessories 01 Front side 02 03 04 09 Blind plug Dimensions Material Part No. Ø 16 mm Stainless steel 82-907 Ø 19 mm Stainless steel 82-908 Ø 22 mm Stainless steel 82-909 14 17 18 19 22 Protective cap Product attributes Dimensions Material Colour Optics Part No.
Accessories 82 Rear side 01 02 Flat receptacle Product attributes Material Part No. 2.8 x 0.5 mm plug-in terminal Metal 31-946 03 04 09 Insulation sleeve Product attributes Material Part No. For flat receptacle 2.8 mm Plastic 31-929 14 17 18 19 22 31 41 45 51 EAO Downloads. www.eao.com/downloads 56 EAO creates possibilities. Since 1947. 57 61 70 71 On our website you can download technical data, assembly instructions, catalogs, brochures and much more. 82 84 92 96 www.eao.
82 Accessories 01 Mounting 02 03 04 09 Fixing nut Dimensions Material Part No. Ø 16 mm Metal 31-991 Ø 19 mm Metal 82-902 Ø 22 mm Metal 82-903 Dimensions Material Part No. Ø 16 mm Metal 82-916 Ø 19 mm Metal 82-917 Ø 22 mm Metal 82-918 Abmessungen Material Part No.
Technical data 82 Indicator, Pushbutton, Illuminated pushbutton Switching system 01 02 Illumination Snap-action changeover contact normally closed / normally open. Switching function momentary or maintain. Material Housing Stainless-steel Stainless-steel chrome-coloured Brass gold-coloured Aluminium natural anodized LED red, green, blue, yellow and white LED and series resistor with polarity protection are built in.
82 Technical data 01 Ambient conditions Climate resistance Damp heat, 21 days as per IEC 60512-11 Storage temperature 02 03 04 – 40 °C … + 80 °C Stainless steel and alumimium versions (without symbol): Saline mist, 96 hours as per EN 60068-2-11 Operating temperature – 30 °C … + 70 °C Brass versions (without symbol): Saline mist, 24 hours as per EN 60068-2-11 Front protection IP65 and IP67, as per IEC 60529 Approvals 09 Impact resistance 14 Shock resistance 17 Degree of pollution 18 19 22
Marking 82 General notes 01 1. Laser marking Using laser technology, the Series 82 stainless steel version can be marked with almost any symbol or text in any language. Laser marking is very resistant, hardly fades and is exceptionally durable. These are the ideal characteristics of vandal-resistant indicators, pushbuttons and illuminated pushbuttons. 02 Therefore, we need electronic DXF-file only. All symbols or texts are marked in anthracite /dark grey. 4.
82 Order examples 01 02 Part number system Series 82 03 04 – Diameter Material Bezel/Lens Connection/ SE Contacts 1 .
Order examples 82 82 01 Order example for pushbutton 82 – 5351.
82 Application guidelines 01 02 03 04 09 14 Suppressor circuits When switching inductive loads such as relays, DC motors, and DC solenoids, it is always important to absorb surges (e. g. with a diode) to protect the contacts. When these inductive loads are switched off, a counter emf can severely damage switch contacts and greatly shorten lifetime. Fig. 1 shows an inductive load with a free-wheeling diode connected in parallel.
Index Part No. Page 01-907.........................24 31-929.........................23 31-946.........................23 31-991.........................24 82-5151.01A4..............18 82-5151.02A4..............18 82-5151.1000................4 82-5151.1000.B001.......4 82-5151.1000.B002.......4 82-5151.1000.B003.......4 82-5151.1000.B004.......4 82-5151.1000.B005.......4 82-5151.1000.B006.......4 82-5151.1114................8 82-5151.1124................8 82-5151.1134................8 82-5151.1144........