Application guidelines
Arrangement mounting flange for switching- and illumination element, PCB mounting
The arrangement of the mounting anges and their number is
determined by the size of the front panel or PCB. To ensure uni
-
form, tactile switching, we recommend a layout of the anges as
per adjacent sketch.
For large PCBs with several switching elements we recommend
the following procedure:
1.
Fit the actuator to the front panel.
2.
Clip the mounting ange to the rear of the intended actuator.
3.
Screw the PCB with the components soldered to it to the
assembled mounting ange.
This arrangement applies to PCBs 1.6
mm thick.
25...30
25...30
max. 60
max. 60
Dismantling mounting flange
The tool Part No. 84-998 must be used for removing the mounting
ange from the actuator.
Before removing the ange, the PCB xing srews must be loo-
sened.
01/2019 § eao.com