Operator’s Manual 800 Watt Inverter Generator SN GAS/OIL RATIO 50:1 Product #: IG800W Get parts online at www.getearthquake.com P/N: OMIG800W ECN: 10526 REV3: 07/11/14 © 2014 Ardisam, Inc.
Operator’s Manual 800 Watt Inverter Generator INTRODUCTION Congratulations on your investment in quality. Thank you for purchasing an IG800W Inverter Generator from Earthquake. We have worked to ensure that the IG800W meets the highest standards for usability and durability. With proper care, your generator will provide many years of service. Please read this entire manual before use. Earthquake reserves the right to change, alter or improve the product and this document at any time without prior notice.
Operator’s Manual 800 Watt Inverter Generator WARNINGS & SAFETY PRECAUTIONS Owner’s Responsibility Accurate assembly and safe and effective use of the machine is the owner’s responsibility. • Read and follow all safety instructions. • Carefully follow the pre-operation check instructions. • Maintain the machine according to directions and schedule included in this Earthquake operator’s manual. • Ensure that anyone who uses the machine is familiar with all controls and safety precautions.
Operator’s Manual 800 Watt Inverter Generator GENERAL SAFETY RULES • Read, understand, and follow all instructions on the machine and in the manual(s). Be thoroughly familiar with the controls and the proper use of the machine before starting. Do not alter the construction of the generator or change controls which might create an unsafe operating condition. • Keep all screws, nuts and bolts tight. 4 • Use this equipment for its intended purpose only.
Operator’s Manual 800 Watt Inverter Generator WARNING WARNING GROUND GENERATOR WITH THE APPROPRIATE AMOUNT OF COPPER FOR CURRENT CAPACITY. USING A GENERATOR INDOORS CAN KILL YOU IN MINUTES DUE TO CARBON MONOXIDE. NEVER USE INSIDE A HOME OR GARAGE. PORTA-0001R1 COPPER DIAMETER 0.005 IN/AMP WARNING ENGINES GIVE OFF CARBON MONOXIDE, AN ODORLESS, COLORLESS, POISONOUS GAS. CARBON MONOXIDE MAY BE PRESENT EVEN IF YOU DO NOT SMELL OR SEE ANY ENGINE EXHAUST.
Operator’s Manual 800 Watt Inverter Generator Gasoline Fires and Handling Fuel Safely Use extra care in handling gasoline and other fuels. They are flammable and vapors are explosive. • When storing extra fuel be sure that it is in an appropriate container and away from any fire hazards. • Prevent fire and explosion caused by static electric discharge. Use only nonmetal, portable fuel containers approved by the Underwriter’s Laboratory (U.L.) or the American Society for Testing & Materials (ASTM).
Operator’s Manual 800 Watt Inverter Generator • Keep all nuts and bolts tight and keep equipment in good condition. • Never tamper with safety devices. Check their proper operation regularly. • When servicing or repairing the machine, do not tip the machine over or up unless specifically instructed to do so in this manual. Service and repair procedures can be done with the machine in an upright position. Some procedures will be easier if the machine is lifted on a raised platform or working surface.
Operator’s Manual 800 Watt Inverter Generator SAFETY DECALS This IG800W Inverter Generator has been designed and manufactured to provide you with the safety and reliability you would expect from an industry leader in powered chore equipment manufacturing. Reading this manual and the safety instructions it contains will provide you with the necessary basic knowledge to operate this equipment safely and effectively.
Operator’s Manual 800 Watt Inverter Generator (Part #16042) IG800W FIRE HAZARD WARNING DECAL Engine Fuel is Flammable (Part # 16065) IG800W NO E85 WARNING DECAL Use Premium Unleaded Gasoline 16035 (Part # 16034) IG800W SPARK PLUG ACCESS DECAL Spark Plug Location (Part # 16035) IG800W FUEL ON-OFF DECAL Fuel Valve ON and Off OFF ARRÊT ON MARCHE PRIMER BULB POIRE D’AMORÇAGE (Part # 16040) IG800W STARTING PROCEDURE DECAL Starting Instructions and Engine Oil Type STARTING INSTRUCTIONS 1.
Operator’s Manual 800 Watt Inverter Generator Features & Controls 11 10 2 1 12 13 16 3 4 5 6 15 7 8 14 9 21 20 17 PORTA-0005R1 19 18 LEGEND: 10 1. ENGINE SWITCH 8. DC RECEPTACLE 15. FUEL VALVE 2. ECONOMY CONTROL SWITCH 9. AC RECEPTACLE 16. CHOKE LEVER 3. OUTPUT LIGHT 10. SPARK PLUG 17. AIR FILTER COVER 4. OVERLOAD INDICATOR LIGHT 11. CARRY HANDLE 18. OIL FILLER CAP 5. OIL WARNING LIGHT 12. PRIMER BULB 19. FUEL TANK 6. DC PROTECTOR 13. MUFFLER 20. FUEL STRAINER 7.
Operator’s Manual 800 Watt Inverter Generator NOTE: It is important to check the oil level before each use. OFF ON RUN STOP OFF ONPUSH FIGURE 1 Engine Switch OPEN CLOSE OPEN The engine switch must be in the RUN position to start and run the generator. Push the engine switch to the STOP position to stop the generator. SEE FIGURE 1 DC PROTECTOR OFF ON CL OS E When the oil level reaches a low level, the engine will stop automatically. In order to restart the engine, the oil must be refilled.
Operator’s Manual 800 Watt Inverter Generator WARNING DO NOT REFILL TANK WHILE ENGINE IS RUNNING OR HOT. ALWAYS CLOSE FUEL VALVE BEFORE REFUELING. BE CAREFUL NOT TO ALLOW DUST, DIRT, WATER OR OTHER FOREIGN OBJECTS INTO FUEL. DO NOT FILL ABOVE THE TOP OF THE FUEL STRAINER OR IT MAY OVERFLOW WHEN THE FUEL EXPANDS. KEEP AWAY FROM OPEN FLAMES. CAUTION ENGINE IS SHIPPED FROM FACTORY WITHOUT OIL. YOU MUST ADD ENGINE OIL BEFORE STARTING ENGINE.
Operator’s Manual 800 Watt Inverter Generator • • • • • • • IF ENGINE FAILS TO START AFTER FOLLOWING STARTING PROCEDURES, PLEASE CONTACT OUR CUSTOMER SERVICE DEPARTMENT AT 800-345-6007. STARTER ROPE CAN CAUSE AN UNANTICIPATED JERK TOWARDS ENGINE. PLEASE FOLLOW INSTRUCTIONS TO AVOID INJURY. NEVER LEAVE ENGINE RUNNING WHILE UNATTENDED. TURN OFF AFTER EVERY USE. NEVER CARRY GENERATOR FROM ONE LOCATION TO ANOTHER WHILE ENGINE IS RUNNING. ALWAYS WEAR A PROTECTIVE HEARING DEVICE.
Operator’s Manual 800 Watt Inverter Generator WARNING DO NOT USE WORN, BARE, FRAYED OR OTHERWISE DAMAGED ELECTRICAL CORD SETS WITH THE GENERATOR. DO NOT HANDLE ANY KIND OF ELECTRICAL DEVICE WHILE STANDING IN WATER, WHILE BAREFOOT OR WHILE HANDS OR FEET ARE WET. USING ELECTRICAL POWER AC Application: 1. Turn off the switch(es) of the electrical device(s) before connecting to the generator. 2. Insert the plug(s) of the electrical device(s) into the receptacle. 3. Start electrical device(s).
Operator’s Manual 800 Watt Inverter Generator MAINTENANCE Generator Maintenance Please read the maintenance schedule and observe these recommendations to extend the life of your generator. Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools.
Operator’s Manual 800 Watt Inverter Generator Steps For Working On Equipment CAUTION ENGINE MUST BE TURNED OFF AND COOL BEFORE CHECKING AND ADJUSTING ENGINE OR EQUIPMENT. TEMPERATURE OF MUFFLER AND NEARBY AREAS MAY EXCEED 150° F (65° C). AVOID THESE AREAS. NEVER STORE ENGINE WITH FUEL IN THE TANK INSIDE A BUILDING. POTENTIAL SPARKS MAY BE PRESENT FOR IGNITION OF FUEL AND FUEL VAPORS. AN ADULT ONLY MUST DO MAINTENANCE AND REPAIR ON GENERATOR.
Operator’s Manual 800 Watt Inverter Generator Air Filter Maintaining an air filter cleaner in proper condition is very important. Dirt induced through improperly installed, improperly serviced, or inadequate filters damages and wears out engines. Keep the filter clean. Cleaning / Replacing Air Filter: 1. Remove the side panel on the starter handle side of the generator by loosening the four screws holding it in place. SEE FIGURE 8 2.
Operator’s Manual 800 Watt Inverter Generator TRANSPORT & STORAGE WARNING DO NOT TRANSPORT GENERATOR INSIDE AN ENCLOSED SPACE OR WITHIN A VEHICLE. FUEL OR FUEL VAPORS MAY IGNITE CAUSING SERIOUS INJURY OR DEATH. Transporting Your Generator 1. After using the generator, and before transporting it, make sure: • the fuel cap is screwed on tightly (clockwise), • the fuel cap vent is closed, • the fuel valve is off. 2.
Operator’s Manual 800 Watt Inverter Generator TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE REMEDY/ACTION Engine will not start 1. Engine switch in STOP position 1. Push engine switch to RUN position 2. Out of fuel 2. Refuel 3. Fuel valve in OFF position 3. Turn fuel valve to ON position 4. Spark plug wire disconnected 4. Connect spark plug wire to spark plug 5. Spark plug wet, faulty or improperly gapped 5. Clean, replace or gap spark plug 6. Economy switch in ON position 6.
Operator’s Manual 800 Watt Inverter Generator PORTA-0010R1 ELECTRICAL WIRE DIAGRAM 20 Check for parts online at www.getearthquake.
Operator’s Manual 800 Watt Inverter Generator ILLUSTRATED PARTS BREAKDOWN 10 7 9 6 4,5 8 3 PORTA-0011R1 4 2 1 KEY PART # DESCRIPTION QTY. KEY PART # DESCRIPTION 1 16116 2 KIT, CIRCUIT BREAKER 4.
Operator’s Manual 800 Watt Inverter Generator ILLUSTRATED PARTS BREAKDOWN 1,2 20 7 2 3,14 3 6 3,15 3,16 3 3,4 4,5 5 4 3,4 4,5 9 4 10 6,7 8 11 12 VIEW A 13 PORTA-0012R1 22 Check for parts online at www.getearthquake.
Operator’s Manual 800 Watt Inverter Generator ILLUSTRATED PARTS BREAKDOWN VIEW A 18 19 PORTA-0016R1 17 KEY PART # DESCRIPTION QTY. 1 16072 SCREW (M4.8 X 13 PPHB GR8.8 BLK OX T/F) 4 2 16111 KIT, RECOIL PANEL SIDE W/ SCREWS 1 3 16086 KIT, AIR FILTER ASSEMBLY WITH CHOKE 1 4 16087 KIT, CARBURETOR REPLACEMENT 1 5 16115 KIT, THROTTLE CONTROL 1 6 16108 KIT, FUEL SYSTEM 1 7 16109 KIT, REMOTE PRIMER BULB W/ 2.
Operator’s Manual 800 Watt Inverter Generator NOTES 24 Check for parts online at www.getearthquake.
Operator’s Manual 800 Watt Inverter Generator IG800W Inverter Generator Warranty Terms and Conditions PRODUCT WARRANTY: 1-YEAR LIMITED WARRANTY Ardisam, Inc., a manufacturing company, warrants this IG800W Earthquake Inverter Generator to be free from defects in the material or workmanship for a period of one year from the date of purchase. During the one-year warranty of this product, Ardisam will furnish, at their discretion, parts and labor to correct any defect caused by faulty material or workmanship.
Operator’s Manual 800 Watt Inverter Generator COMBINED EXHAUST AND EVAPORATIVE EMISSIONS CONTROL WARRANTY STATEMENT Your Warranty Rights And Obligations The California Air Resources Board, the United States Environmental Protection Agency and Ardisam, Inc. (Ardisam), are pleased to explain the emission control system warranty on your 2014 model year small off-road engine/equipment.
Operator’s Manual 800 Watt Inverter Generator (4) Repair or replacement of any warranted part under the warranty must be performed at no charge to the owner at a warranty station. (5) Notwithstanding the provisions of subsection (4) above, warranty services or repairs must be provided at all Ardisam distribution centers that are franchised to service the subject engine/equipment.
Earthquake™, Division of Ardisam, Inc. 1160 8th Avenue, PO Box 666 Cumberland, WI 54829 800-345-6007 | Fax 715-822-2223 E-mail: info@Ardisam.com All weights, specifications and features are approximate and are subject to change without notice. Due to continuous product improvements, product images may not be exact. Items used for props not included. Some assembly may be required. Check for parts online at www.getearthquake.