Instruction manual

4-8
4.3 Maintenance of Air CompressorOnly for P/N 539-9010 and 539-9060
NOTICE
Instruments shipped to Europe area where CE marking conformity is necessary do not provide
with the air compressor. Also instruments those shall be compliant to SEMI-S2 guideline do not
provide with the air compressor even when shipped to outside of Europe area.
4.3.1 Checkup and Maintenance
Check the following items regularly.
Before checkup/maintenance, be sure turn the main switch off.
Service Cycle
Check Item Procedure
Every
day
Every
250 h
(1 month)
Every 3,000 h
(1 year)
Every 6,000 h
(2 years)
Discharge of drain Loosen the drain
cock of air tank to
discharge drain.
Activation of control
devices (pressure
gauge, pressure switch
and safety valve)
Check the
working pressure
and activated
function.
Abnormal vibration and
abnormal sound
Loose bolts, nuts and
screws
If loose, retighten
them.
Contamination and
clogging of strainer/filter
Blow air to
remove clogged
substance.
Leakage through air
valve
Piston ring
Rider ring
Ball bearing
Bearing
Needle roller
bearing
CAUTION
The air compressor should be drained gradually by slowly loosening the drain cocks.
The inside of tank is at a high pressure. So, refrain from an abrupt cock operation,
otherwise moisture may spray out to cause a danger.