Operator's Manual WP4310 43cc Water Pump ARDISAM .com OMWP4310 Rev. 12-17-09 © 2009 Ardisam, Inc. All Rights Reserved.
Operator's Manual WP4310 43cc Water Pump INTRODUCTION, REGISTRATION AND WARRANTY Thank You . . . for purchasing an EarthquakeTM Water Pump from Ardisam, Inc. We have worked to ensure that our product meets high standards for usability and durability. Please take the time to read this manual carefully to learn how to correctly operate and maintain your water pump. Congratulations on your investment in quality. Federal Emission Information Ardisam, Inc.
Operator's Manual WP4310 43cc Water Pump SAFETY Owner’s Responsibility It is the owner’s responsibility to accurately assemble the pump for safe and effective use. • Read and follow all safety instructions. • Carefully follow all assembly instructions. • Maintain the pump according to directions and schedule included in this Earthquake operator's manual. • Ensure that anyone who uses the pump is familiar with all controls and safety precautions.
Operator's Manual WP4310 43cc Water Pump Engine Safety Precautions Prevention of Gasoline Fires Warning Carbon Monoxide Poisoning All engine exhaust contains carbon monoxide. Carbon monoxide is a deadly, colorless, tasteless, odorless gas which may be present even if you do not smell or see engine exhaust. Levels of carbon monoxide, which can be deadly, can be present for days in an enclosed area that has poor ventilation.
Operator's Manual WP4310 43cc Water Pump Burns and Fires The muffler, muffler guard and other parts of the engine become extremely hot during the operation of the engine. These parts remain extremely hot after the engine has stopped. This engine is designed to operate using a catalytic converter which contributes to the engine’s compliance with the EPA. Prevention of Burns and Fires • Never remove the muffler guard from the engine.
Operator's Manual WP4310 43cc Water Pump Mixing Fuel and Filling Fuel Tank CAUTION Avoid injury! Never store engine with fuel in the tank indoors. Fuel and fuel vapors are highly flammable. Filling Fuel Tank 1. Shut-off engine and allow engine to completely cool before filling the fuel tank. 2. Move to a well ventilated area or outdoors away from flames and spark. 3. Clean debris from area around the fuel cap. 4. Loosen fuel cap slowly. Place the cap on a clean, dry surface.
Operator's Manual WP4310 43cc Water Pump OPERATION Starting and Stopping Engine 9. After engine starts running, move choke lever to 1. Move engine to a well ventilated area or outdoor to prevent carbon monoxide poisoning. half choke. 10. Move choke lever to OFF or RUN position and move throttle to desired speed. 2. Move to an area away from flames or sparks to avoid ignition of vapors if present. 3. Remove all debris from air cleaner holes and fuel cap to ensure proper air flow.
Operator's Manual WP4310 43cc Water Pump MAINTENANCE AND STORAGE ENGINE MAINTENANCE CAUTION To prevent accidental starting: Avoid injury! Engine must be turned off and cool, and spark plug wire must be removed from spark plug before checking and adjusting engine or equipment. CAUTION Avoid injury! Temperature of muffler and nearby areas may exceed 150° F (65° C). Avoid these areas. CAUTION Avoid injury! Check pump often for loose nuts and bolts. Keep these items tightened. Pump Maintenance 1.
Operator's Manual WP4310 43cc Water Pump Cooling Fins • Cooling fins, air inlets and linkages must be free from any debris before each use. Air Filters • Never run engine without air cleaner properly installed. Added wear and engine failure may occur if air cleaner is not installed on engine. • Service air cleaner every 3 months or after 20 hours of operation. Clean more frequently if engine is operated in extremely dusty conditions. Steps for Cleaning Air Filters Transporting Your Water Pump 1.
Operator's Manual WP4310 43cc Water Pump SERVICE, TROUBLESHOOTING AND REPAIR Service Information Ordering Repair Parts Parts can be obtained from the store where your water pump was purchased or direct from the factory. To order from the factory, call or write to: IN CASE OF A SERVICE PROBLEM, DO NOT SEND UNIT BACK TO RETAILER. CONTACT ARDISAM, INC. AT 800-345-6007. WE WELCOME YOUR CALL. ARDISAM .com At Ardisam, we build quality and durability into the design of our products.
Operator's Manual WP4310 43cc Water Pump SERVICE, TROUBLESHOOTING AND REPAIR CAUTION Practice safety at all times. Engine must be turned off and allowed to cool, and spark plug wire must be disconnected before attempting any maintenance or repair. Troubleshooting Problem Possible cause Engine will not start 1. Power switch off 2. Spark plug wire disconnected 3. Spark plug has no spark 1. Flip switch to on position 2. Connect spark plug wire to spark plug 3.
Operator's Manual WP4310 43cc Water Pump WP4310 WATER PUMP ENGINE BREAKDOWN Check for parts online at www.getearthquake.
Operator's Manual WP4310 43cc Water Pump 10 23 24 25 33 34 4 6 14 3 2 3 42 1 2 3 4 5 7 6 39 40 8 10 9 9 41 11 12 35 2 4 14 2 3 16 16 15 17 23 19 20 24 21 22 25 31 26 29 30 29 28 27 31 28 32 36 37 10 WP4310 WATER PUMP BREAKDOWN Check for parts online at www.getearthquake.
Operator's Manual WP4310 43cc Water Pump WP4310 WATER PUMP PARTS LIST MINIMUM ORDER............................................................................................................$10.00 ENGINE PARTS Part # Description Qty. 1021 switch, Rocker...................................................................1 300429 plate, Recoil.........................................................................1 300430 Recoil Assembly................................................................
Operator's Manual WP4310 43cc Water Pump WP4310 Water Pump Warranty Terms and Conditions Product Warranty: 1-Year Limited Warranty Ardisam, Inc., a manufacturing company, warrants this Earthquake® Water pump to be free from defects in the material or workmanship for a period of one year from the date of purchase. During the one year warranty of this product, Ardisam will furnish 100% parts and labor to correct any defect caused by faulty material or workmanship.
Operator's Manual WP4310 43cc Water Pump Explanation of Emissions Control Warranty Provisions Viper Engines are designed, built and equipped to meet all EPA requirements. It warrants that it is free from defects in material and workmanship that could cause failure to the warranted part; and that it is identical in all material respects to the engine described in the manufacturer's application for certification.
Operator's Manual WP4310 43cc Water Pump NOTES _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _______________________________________________________________________________________
Operator's Manual WP4310 43cc Water Pump NOTES _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _______________________________________________________________________________________
Earthquake™, Division of Ardisam, Inc. 1160 8th Avenue, PO Box 666 Cumberland, WI 54829 800-345-6007 | Fax 715-822-2223 Email: info@ardisam.com Check for parts online at www.earthquake.