OMWP4310 Rev .3/ 24/ 09 2009Ar di sam,I nc. Al lRi ght sReser v ed.
EARTHQUAKE, Division of Ardisam, Inc.
INTRODUCTION, REGISTRATION AND WARRANTY THANK YOU . . . for purchasing an Earthquake® Water Pump from Ardisam, Inc. We have worked to ensure that our product meets high standards for usability and durability. Please take the time to read this manual carefully to learn how to correctly operate and maintain your water pump. Congratulations on your investment in quality. CONTENTS Registration/Warranty .............................................3 Safety .......................................................
SAFETY OWNER'S RESPONSIBILITY IMPORT ANT SAFETY PRECAUTIONS IMPORTANT It is the owner’s responsibility to accurately assemble the pump for safe and effective use. Please read this section carefully. Operate the water pump according to the safety instructions and recommendations outlined here and inserted throughout the text. Anyone who uses this water pump must read the instructions and be familiar with the controls. • Read and follow all safety instructions.
SAFETY ENGINE SAFETY PRECAUTIONS Warning Carbon Monoxide Poisoning All engine exhaust contains carbon monoxide. Carbon monoxide is a deadly, colorless, tasteless, odorless gas which may be present even if you do not smell or see engine exhaust. Levels of carbon monoxide, which can be deadly, can be present for days in an enclosed area that has poor ventilation. Any level of carbon monoxide, if inhaled, can cause headaches, drowsiness, nausea, dizziness, confusion and eventually death.
SAFETY BURNS AND FIRES The muffler, muffler guard and other parts of the engine become extremely hot during the operation of the engine. These parts remain extremely hot after the engine has stopped. This engine is designed to operate using a catalytic converter which contributes to the engine’s compliance with the EPA. Prevention of Burns and Fires • Never remove the muffler guard from the engine. 3. Securely place the disconnected spark plug wire away from the spark plug and any metal parts.
OPERA TION OPERATION MIXING FUEL AND FILLING FUEL TANK CAUTION Avoid injury! Never store engine with fuel in the tank indoors. Fuel and fuel vapors are highly flammable. Filling Fuel Tank 1. Shut-off engine and allow engine to completely cool before refilling the fuel tank. 2. Move to a well ventilated area or outdoors away from flames and sparks. 3. Clean debris from area around the fuel cap. 4. Loosen fuel cap slowly. Place the cap on a clean, dry surface.
OPERA TION OPERATION ST ARTING AND ST OPPING ENGINE STARTING STOPPING 1. Move engine to a well ventilated area or outdoors to prevent carbon monoxide poisoning. 2. Move to an area away from flames or sparks to avoid ignition of vapors if present. 3. Remove all debris from air cleaner holes and fuel cap to ensure proper air flow. 4. Turn switch to the ON position. 9. After engine starts running, move choke lever to HALF CHOKE. 10. Move choke lever to OFF or RUN position and move throttle to desired speed.
MAINTENANCE AND ST ORAGE STORAGE Cooling Fins CAUTION To prevent accidental starting: Avoid injury! Engine must be turned off and cool, and spark plug wire must be removed from spark plug before checking and adjusting engine or equipment. CAUTION Avoid injury! Temperature of muffler and nearby areas may exceed 150° F (65° C). Avoid these areas. • Cooling fins, air inlets and linkages must be free from any debris before each use. Air Filters • Never run engine without air cleaner properly installed.
MAINTENANCE AND ST ORAGE STORAGE TRANSPORTING YOUR WA TER PUMP WATER LONG TERM ST ORAGE STORAGE 1. Never transport engine inside an enclosed space or vehicle. Fuel or fuel vapors may ignite causing serious injury or death. • If your pump will not be used for more than one month, prepare it for long term storage. 2. If fuel is present in the fuel tank, transport in an open vehicle in an upright position. 3. If an enclosed vehicle must be used, remove gas into an approved red gasoline container.
SERVICE TING AND REP AIR SERVICE,, TROUBLESHOO TROUBLESHOOTING REPAIR SERVICE INFORMA TION INFORMATION ORDERING REP AIR PARTS REPAIR Parts can be obtained from the store where your water pump was purchased or direct from the factory. To order from the factory, call or write to: IN CASE OF A SERVICE PROBLEM, DO NOT SEND UNIT BACK TO RETAILER. CONTACT ARDISAM, INC. AT 800-345-6007. WE WELCOME YOUR CALL. At Ardisam, we build quality and durability into the design of our products.
SERVICE TING AND REP AIR SERVICE,, TROUBLESHOO TROUBLESHOOTING REPAIR CAUTION Practice safety at all times. Engine must be turned off and allowed to cool, and spark plug wire must be disconnected before attempting any maintenance or repair. TROUBLESHOO TING TROUBLESHOOTING Problem Possible cause Remedy/Action Engine will not start 1. Power switch off 2. Spark plug wire disconnected 3. Spark plug has no spark 1. Flip switch to on position 2. Connect spark plug wire to spark plug 3.
EARTHQUAKE, Division of Ardisam, Inc.
Earthquake, A Division of Ardisam, Inc. 1690 Elm Street, Cumberland, Wisconsin 54829 Phone (715)822-2415 • Main Fax (715)822-2223 1-800-345-6007 Email info@ardisam.