Full Product Manual

Assembly and Operation Instructions
P2170_M52164_Rev_May2020_compressed PAGE 11
Broadcast Setting Matrix
Calibration Techniques
How to ensure your spreader is properly calibrated
Make sure the drop holes in the bottom of the hopper are fully open when the Rate Control handle is on #30. If not,
please adjust control cable or control rod to allow for a full open hopper position at #30.
Rod Type Adjustment
1. Open the shut-off so that the drop holes are completely open as
illustrated to the right.
2. Review the Control Lever positionif it is set so that the forward
edge is at #30, you are calibrated. If not, you need to adjust the
control rod at the pivot bracket shown in Fig 1.
A. If your shut-off is not able to open fully as in step #1. Loosen
the top nut a few turns, then loosen the lower nut so that it
allows you to push the shut-off open fully. Next tighten each
nut so that they contact the pivot bracket without moving it,
and then carefully tighten each nut fully so they do not loosen
during use. Recheck adjustment as outlined in #1 above.
B. If your shut-off is able to open fully as in step #1, but the
Control Lever is not at #30. Loosen the top nut a few urns, then
loosen the lower nut so that it allows you to push the Control
Lever to #30. Next tighten each nut so that they contact the pivot bracket without moving it. Carefully tighten
each nut fully so they do not loosen during use. Recheck adjust as outlined in #1 above.
Cable Type Adjustment
1. Open the Control Lever so that the shut-off and drop holes are completely open as illustrated above right.
2. Review the Control Lever position so that the indicator is pointed to #30, if it is your calibration is correct. If not you
need to adjust the control cable at the cable clamp on the underside of the hopper as shown in Fig 2.
A. If your shut-off is not able to open fully as in step #1. Loosen the cable clamp screw slightly so that you can slide
the outer cable out so that the shut-off is fully open. Next tighten the cable clamp screw securely. Recheck
adjustment as outlined in #1 above.
B. If your shut-off is able to open fully as in step #1, but the Control Lever is not at #30. Loosen the cable clamp
screw slightly so that you can slide the outer cable in so that the Control Lever opens to #30. Next tighten the
cable clamp screw securely. Recheck adjustment as outlined in #1 above.
If you have any questions regarding the operation or assembly of your spreader please call us at 574-848-7491 Monday -
Friday 9:00am - 4:00pm Eastern. Accessories and Repair Parts are also available at these numbers.