Horizontal length of each roof section to
be protected, in feet ..................
Depth of overhang for each roof section,
in inches ...........................
Each dormer up, over and down
per diagram, in feet ..................
Length of each downspout, in feet......
Note number of roof intersection valleys
CALCULATION BY SECTION
A. For each section overhang depth, find
the multiplier table ..................
B. If the section has no gutter, subtract
1.0 from the multiplier ...............
C. Multiply length of each roof section by
its overhang multiplier ...............
D. Total all the section dormer
measurements ......................
E. For each downspout with cable running
down and back up, typically all but the
last one on a cable run, multiply length
by 2 and add together ...............
F. Total length of downspouts with cables
running down only, typically the last
one in a cable run ...................
G. Multiply the number of valleys by 6....
TOTAL ITEMS C-G
www.easyheat.com
40400-001 Rev. 5 Printed in U S A © 2007 EASYHEAT
ADKS Series
120 VOLTS
CATALOG NUMBER LENGTH WATTS
ADKS-100 20´
(
6 m
)
100
ADKS-150 30´
(
9 m
)
150
ADKS-300 60´
(
18 m
)
300
ADKS-400 80´
(
24 m
)
400
ADKS-500 100´
(
31 m
)
500
ADKS-600 120´
(
37 m
)
600
ADKS-800 160´
(
49 m
)
800
ADKS-1000 200´
(
61 m
)
1000
ADKS-1200 240´
(
73 m
)
1200
USA
2 Connecticut South Drive
East Granby CT 06026
Tel 800/537-4732
Fax 800/541-7451
Canada
99 Union Street
Elmira ON N3B 3L7
Tel 519/669-2444
Fax 519/669-6419
PREVENT ROOF
DAMAGE AND
LEAKING
KEEP GUTTERS &
DOWNSPOUTS
FLOWING
PREASSEMBLED
READY-TO-INSTALL
Easy Heat products are provided with a
LIMITED WARRANTY:
see owner’s manual or contact Easy Heat
for complete terms and conditions.
Electric Roof
De-icing Cable
Stop Damaging
Roof-Ice Buildup