Install Instructions
Table Of Contents
INSTALLATION INSTRUCTIONS
1. Mount the TS-1 securely to a wall or fascia by 2 No.8 screws. Mount in a location that has the same weather conditions
as the snow and ice melting zones. Avoid direct sunlight or warm exhaust vent areas as this may cause erroneous
temperature readings. The unit is water-resistant, but it is not designed to be submerged or immersed in water. Ensure
that the mounting location is close (less than 10 feet) to the MSC-1 Control Panel or a suitable connection box. See Fig.2.
2. The TS-1 connection wire may be extended up to 500’ with an appropriately rated 18-20AWG 3 wire unshielded cable.
Ensure that all electrical connections within connection boxes are sealed to prevent any penetration of water.
3. The TS-1 is wired directly to the temperature sensor terminal block of the MSC-1 control panel.
Figure 2 - TS-1 connection to MSC-1
indoor location
#8
screws
TS-1
Extend to 500´ max;
18 – 20 AWG,
3 conductor unshielded
stranded cable
Access
Cover
MSC-1
Control Panel
TS-1 Installations & Operation Instructions
©2009 Easy Heat www.easyheat.com 14067-001 Rev. 4