Installation guide
22
EASYTOUCH
®
PL4/PSL4 Control System Installation Guide
CablingtheIndoorControlPanelatthePowerCenter
To connect the indoor control panel cable to the board:
1. Turn off the main system power before making any connections.
2. Run a UL approved four conductor cable (22 AWG) from the indoor control panel to the
Power Center. The preferred wire color scheme is: Red, yellow, green, and black.
3. Route the cable up through the low voltage raceway to the motherboard.
4. Strip back the communication cable conductors ¼ in. Insert the wires into the screw
terminals(providedinthekit).Securethewireswiththescrews.Makesuretomatchthe
color-coding of the wires: Red = +15, Yellow = +DT, Green = -DT, and GND = Black.
5. Insert the cable plug onto the COM-PORT(J20) connector.
6. Proceed with MountandCabletheIndoorControlPanel, page 23.
IntelliFlo Pump
COM Port
COM PORT - J20 connector: For IntelliFlo
®
Pump, iS4 Spa Side Remote QuickTouch
®
,
PL4/PSl4 Control System Indoor Control
Panel and Pl4/PSL4 Control System
Wireless Controller Transceiver.
EasyTouch PL4/PSL4 Control System Circuit Board
ConnectingtheIndoorControlPanelCabletotheEasyTouch
®
PL4/PSL4
Control System Outdoor Power Center
BEFORE INSTALLING THE Power Center AND POWER CENTER, ALWAYS
SWITCHOFFTHEMAINPOWERintothehomeatthemaincircuitbreakerbox.