Mounting Instructions Item No.: 231.98.
Notes on this manual ® Copyright 2010 by Document number: Schulte-Schlagbaum AG Nevigeser Straße 100-110 D-42553 Velbert Phone: +49 2051 2086-0 http:/www.sag-schlagbaum.com 6-703-2 34R1.0 • This manual replaces all previous versions. • The details in this manual are subject to change without prior notification. • The compilation of the information in this manual is carried out to the best of our knowledge.
Table of Contents Notes on this manual..................................................................................... Safety and warning notes............................................................................. Table of contents............................................................................................ Control elements............................................................................................ Lock with mounting components......................................
Control Elements LED display red / green Exchangeable plate Rotary knob Capacity keypad √ OK key: Finish of Code entry Abort key: Code entries or programming operations can be rejected by X pressing the abort key 1 2 3 4 5 6 7 8 9 0 Keys 1, 2, 3, 4, 5, 6, 7, 8, 9, 0: Number keys for Code entry 4
Lock with Mounting Components 1 2 3 4 5 6 7 8 9 Lock Nut for mounting the lock on the door Grommet for setting the rotational direction of the rotary knob in order to lock Locking cam (A cropped or hook-shaped locking lever can also be used depending on the properties and condition of the cabinet.
Installation Information Preparation of the door The following holes must exist in the door corresponding to the drawing: 1. Punched hole, dimensions 19.1 mm / 16 mm. A round hole with a diameter of 19.1 mm can also be drilled at this position. 2. Round hole with a diameter of 7 mm. As soon as the first hole exists, as described in 1, the 7 mm round hole can be drilled by using a drilling template (e.g. the drilling template at the end of the manual). Installation 1. 2. 3. 4. 5. 6.
Installation Information Settng the rotational direction for locking The setting of the rotational direction described here is for a lock with a rotary knob that is turned to the left for locking. 1 Lock marked with left handed rotational direction for locking 2 Grommet that is attached to the lock on the inside of the door. The opening marked “L” points downwards. 3 Rear side of the lock to which the grommet is attached. If the lock is installed in a position whereby the rotary knob is not at the top (e.
Installation Information Replacing the plate (e.g. for numbers, logo, etc.) After inserting a small screwdriver into the center of the plate, the old plate is levered out of the lock. A new plate can then be snapped in. Notice: The old plate is destroyed when the plate is replaced.
General Information Capacitive keypad The SAFE-O-TRONIC® LS 100 uses a capacitive keypad. Notice: The capacitive keypad cannot be operated if you are wearing gloves. UserCode The UserCode serves locking or opening of the cabinet or locker by the user. Any four-digit code can be programmed as the UserCode. MasterCode1 MasterCode1 serves the plant operator to open the locker. It is intended for employees with restricted locking authorizations.
General Information Operation Operation is supported by the red/green LED display and an acoustic acknowledgement by means of signal transmitters. The X key can be used to abort an input procedure. The procedure is aborted automatically if there is a stop of more than three seconds between operating the individual keys. You have four attempts to enter the correct code. After the fourth incorrect entry the entry process is disabled for one minute as protection against manipulation.
Initial Operation For initial operation every SAFE-O-TRONIC® LS 100 lock has to be programmed using MasterCode2. Please note: Please make sure that unauthorized persons do not gain knowledge of the programmed MasterCode2.
Initial Operation Locking and opening using MasterCode2 The operator of the facility can use MasterCode2 at any time to open or lock the locker fitted with the SAFEO-TRONIC® LS 100. ► 3 Entering MasterCode2 5 1 9 7 Notice: 3, 5, 1, 9, 7 is only an example code! ► √ Then press the OK key ► Turn the knob Locking and opening using the UserCode The user has the possibility to enter a random 4-digit UserCode and lock and open the locker.
Further Functions Altering MasterCode2 ► Press the OK and abort keys simultaneously √ and ► Enter active MasterCode2 3 5 X 1 9 7 2 7 3 2 7 3 Notice: 3, 5, 1, 9, 7 is only an example code! ► Press the OK key √ ► Press 2 (“2” for MasterCode2) 2 ► Press the OK key ► Enter new MasterCode2 √ 4 8 Notice: 4, 8, 2, 7, 3 is only an example code! ► Press the OK key ► Enter new MasterCode2 one more time ► Press the OK key √ 4 8 √ 13
Further Functions Programming MasterCode1 MasterCode1 is not activated in the factory and must be programmed by the operator. Notice: An identical code for MasterCode1 and MasterCode2 is not permitted.
Further Functions Opening using MasterCode1 After programming, a locker can be opened with the help of MasterCode1. ► Enter MasterCode1 3 ► Then press the OK key √ 5 1 9 7 Release using MasterCode2 If a compartment that is fitted with a SAFE-O-TRONIC® LS 100 is opened using MasterCode1, it stays blocked for the entry of a UserCode. The SAFE-O-TRONIC® LS 100 then has to be released again using MasterCode2.
Further Information LED Display All important actions and operating conditions are indicated by the LED display and are intended to contribute to finding the causes of failures and operating errors. The following table lists the meaning of the individual signals. Status messages: green red green red Display Flashing rapidly 1 second Action Programming mode Mastercode 1 & 2 Blocking time (one minute) is active.
Troubleshooting / Operating Errors You are able to see errors and operating errors in the status messages of the LED display and then correct them accordingly. Reset should be carried out in the case that other non-defined conditions arise and the lock does not operate flawlessly even though the battery has been replaced. This resets the lock to factory default settings and all programming is deleted. You can obtain the instructions for this via the address or telephone number stated on page 2.
Technical Data Indicators: Acoustic signal: Battery: Battery life cycle: Temperature ranges Function: Storage: Relative humidity: Protection class according To DIN EN 60529: Weight: Housing dimensions incl. Rotary knob (H x W x D): Color of housing frame: Color of the control panel: Door thickness: 18 2 x LED green 2 x LED red Signal transmitter Battery pack: 3 x alkaline cells (AAA) Approx.
Further Functions Technical Data Notice: Depending on the printer there can be dimensional deviations when printing this drilling template. Therefore, please re-measure the drilling template before use! 3901 Cheyenne Drive P.O. Box 4000 Archdale, NC 27263 1-800-423-3531 www.hafele.