DDF7001 Processor Connections
If your receiver has an RSSI analog, connect it to the blue wire, RSSI Input, with the white wire
grounded to the receiver. Additionally, you must connect the coaxial cable from the DF
antenna to the receiver antenna input.
5 ft end to end
1
2
CON281 (3.5mm)
Audhigh
CAB355 (AWG22ORG)
4
5
6
1
2
3
CON270/264
Audlow
CAB302 (AWG22VIO)
Ground
RSSIinput
View from Wiring End.
CAB170 (AWG22 BLU)
CAB354 (AWG22 WHT)
TWISTED
PAIR
TWISTED
PAIR
CON270 is Molex 39012065 receptacle.
CON264 are Molex 39000182 female terminals.
CON281 is Kobicon 171-3235-EX
3.5mm mono plug.
RECEIVER CONTROL
For the USB receivers connect the USB cable provided with your receiver to either of the USB
host ports on the DDF7001. For receivers that require a serial port you need to connect a
USB-to-Serial converter to one of the USB host ports and then connect the receiver to the
serial port. See the USB-to-Serial Converter section of this manual for further information.
Figure 26: Receiver Connections