User`s manual

43
43
Command
Name
Command
Number
Data
Length
Range Comments
Sweep Rate
0x0001
byte
0
-
4
0 = 0, 1=250,2=500.
3=1000
,4
=2000
Averages
0x0002
byte
1
-
20
Default is 2
Attenuator
0x0003
byte
0
–
1
0 = off
, 1 = on
Audio Volume
0x0004
byte
0
–
96
0 = max volume, 96 = muted,
default 20
Reserved for future use
0x0005
Receiver Type 0x0006 byte 0 – 4 0 = ICOM R8500
1 = ICOM PCR1500
2 = ICOM PCR2500
3 = AOR AR8600
4 = AOR AR5000
If the receiver requires a serial port and no serial port has been
assigned for the receiver then serial port 0 will be assigned to
the receiver
Sample Time 0x0007 short 10 – 10000 Sample time in ms Maximum value 1500 ms
Default 500 ms
Reserved for future use
0x0008
Threshold 0x0009 short 10 – 10000 Sets the maximum separation of consecutive bearing
measurements that will be used in the bearing calculation.
Setting this number low will result in some missed bearings.
Setting it high will result in more false positives.
Default 4000