Cut Sheet

Data subject to change without notice. Consult local utility for area acceptance. All dimensions in inches.
76
5
Bussed Gutters
1Ø 3W
CONDUCTOR LUG RANGE
DIMENSIONS (INCHES)
C
ATALOG METER AIC
AMPACITY VOLTAGE
PHASE CONDUCTOR NEUTRAL FIGURE HEIGHT WIDTH DEPTH
NUMBER POSITIONS RATING LINE LOAD*CONDUCTOR** NUMBER (H) (W) (D)
R1122HC 2 10K 400 600 (1) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 1 13 28
3
8 6
R1123HC 3 10K 400 600 (1) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 2 13 42
3
4 6
R1123HD 3 10K 600 600 (2) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 2 22 42
3
4 6
R1124HD 4 10K 600 600 (2) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 3 22 57 6
R1125HD 5 10K 600 600 (2) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 4 22 71
1
4 6
R1126HD 6 10K 600 600 (2) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 5 22 85
5
8 6
R1124HE 4 10K 800 600 (3) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 3 22 57 6
R1125HE 5 10K 800 600 (3) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 4 22 71
1
4 6
R1126HE 6 10K 800 600 (3) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 5 22 85
5
8 6
3Ø 4W
CONDUCTOR LUG RANGE
DIMENSIONS (INCHES)
C
ATALOG METER AIC
AMPACITY VOLTAGE
PHASE CONDUCTOR NEUTRAL FIGURE HEIGHT WIDTH DEPTH
NUMBER POSITIONS RATING LINE LOAD*CONDUCTOR** NUMBER (H) (W) (D)
R1122HCC 2 10K 400 600 (1) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 1 22 28
3
8 6
R1123HCC 3 10K 400 600 (1) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 2 22 42
3
4 6
R1123HDD 3 10K 600 600 (2) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 2 22 42
3
4 6
R1124HDD 4 10K 600 600 (2) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 3 22 57 6
R1125HDD 5 10K 600 600 (2) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 4 22 71
1
4 6
R1126HDD 6 10K 600 600 (2) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 5 22 85
5
8 6
R1124HEE 4 10K 800 600 (3) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 3 28
1
2 57 6
R1125HEE 5 10K 800 600 (3) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 4 28
1
2 71
1
4 6
R1126HEE 6 10K 800 600 (3) 4 AWG - 600 kcmil 6 AWG - 600 kcmil 4 AWG - 600 kcmil Fig. 5 28
1
2 85
5
8 6
APPLICATION
• Type 3R construction
• Aluminum bussing
• Knockouts on bottom end for AW hub opening
CONSTRUCTION
• For ganging TB – MTB – MTBP or MTBH units
under common feed
• UL 1773 listed
Note: For underground feed most utilities require the
use of underground termination enclosure series
“R-9000” (page 82) ahead of bussed gutters.
STANDARDS
R1122HC
* = Load lugs pre-installed - one set per meter position
** = Ground lug secured to neutral bus 6 AWG - 250 kcmil
Test Block Bypass Metering
400-800 Amp/600 Volt Bussed Gutters