Specification Sheet

Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Voltage
(1)
Options
Emergency
EL7W=7-watt, 120V-277V emergency
battery pack installed
(4)
EL14W=14-watt 120V-277V emergency
battery pack installed
(4)
GTD2=Bodine Generator Transfer Device
(12)
ETS2=IOTA Emergency Transfer Switch
(12)
CCT
L830=3000K
L835=3500K
L840=4000K
Flex
(11)
Multiple Configurations Available
Optics
Blank=Standard
Series
(7)
22EN=2' x 2' Encounter Series
ACCESSORIES
T3A END E.Q. BRACKET PARTS BAG (Standard with fixture)
DF-22-W=2' x 2' Drywall Frame Kit
SK-22-WS=2' x 2' Shallow Surface Mount Kit
SK-22-WT=2' x 2' Tall Surface Mount Kit
DF10P-C =Decorator Dimmer, 0-10V
SF10P- =Decorator Slide Dimmer, 0-10V
ISHH-01=Programming Remote for Integrated Sensor
ISHH-02=Personal Control Remote for Integrated Sensor
Rating
Blank=Standard
ATW-SW4=Chicago
Rated
(8)
Lamp Type
LD2=LED 2. 0
Stock Lumen Outputs
25=2500 Lumens
34=3400 Lumens
MTO Lumen Outputs
19=1900 Lumens
30=3000 Lumens
39=3900 Lumens
43=4300 Lumens
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
(2)
Must be used in conjunction with a DALI control system. For complete DALI solutions by Fifth Light, visit
www.eaton.com/lightingsystems
(3)
1900, 2500, 3000 and 3400 lumen option are not available with a Fifth Light DALI (5LTD) driver.
(4)
With integral test switch/indicator/laser test. For approximate delivered lumens
multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available.
(5)
Step-dim
driver not available with 1900, 2500, 3000 and 3400 lumen option.
(6)
347V emergency option not available.
(7)
DesignLights Consortium
®
Qualified and classified for DLC Standard, refer to www.designlights.org for
details.
(8)
Chicago rated version does not allow for row mounting.
(9)
Air version is vented but does not meet air handling requirements; a 6% reduction in delivered lumens is experienced with this option.
(10)
Integral
sensors work with CD and HCD drivers only and is factory prewired to the driver for stand-alone control.
(11)
Flex does not include dimming leads. Control leads provided by others.
(12)
Used to transfer fixture to
secondary power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power. Add 120V, 277V, or 347V if
ordering GTD2 or ETS2 emergencies.
(13)
SR driver compatible with LWI option only.
(14)
LWT compatible with CD and HCD drivers only.
(15)
LWT sensor is external to luminaire, cable factory wired. Must be used in
conjunction with a LumaWatt Pro control system. For complete LumaWatt Pro wireless solutions, visit www.eaton.com/lumawattpro.
Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information.
(3), (5)
(3), (5)
Driver Type
5LTD=Fifth Light DALI Driver
(10% - 100% Dimming)
(2), (3)
5LTHD=Fifth Light DALI Driver
(1% - 100% Dimming)
(2)
SR=Sensor Ready
(1% - 100% Dimming)
(13)
CD=0-10V Dimming Driver
(10% - 100% Dimming)
HCD=0-10V Dimming Driver
(1% - 100% Dimming)
SD=Step-dim Driver
(5)
Number of Drivers
1=1 Driver
Packaging
U=Unit Pack
PALC=Job
Pack, in carton
Product Family
S=Integrated Sensor
L=LumaWatt
Control Type
B=Sensor Mounting, No Sensor
V=Analog (0-10V) Output for Local Control
(10)
W=WaveLinx
(10)
WI=Wireless Integral
(13)
WT=Wireless Tile
(14, 15)
Occupancy Technology
P=Passive Infrared
Sensing Technology
D=Dimming Daylight
Harvesting (Closed Loop)
Coverage Pattern
1= ~144 Square Feet
Air
[Blank] =Standard
A=Air (Vented)
(9)
L850=5000K
(3), (5)
(3), (5)
UNV=Universal Voltage 120-277
347V=347 Volt
(6)
ORDERING INFORMATION
Catalog No. Wt.
22EN-LD2-25 14 lbs.
22EN-LD2-34 14 lbs.
SHIPPING DATA
PS519064EN
11-27-2017
22EN LED 2’ X 2’