Specification Sheet
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
HALO
®
H
38LVICAT is an IC AIR-TITE™ fixture for use with H3 3" series trims.
Housing is AIR-TITE rated to prevent airflow between heated or air
c
onditioned spaces and unconditioned attic areas. For use with 12V MR16
lamps.
H
38LVICAT is IC rated and may be used in insulated ceilings and be
covered with insulation material.
DESCR I P T I O N
SPEC I F I C AT I O N FEATU R E S
H
ou s i ng
I
C and AIR-TITE rated double wall
aluminum construction.
Pl a s ter Frame
Housing adjusts in plaster frame to
a
ccommodate up to 1-1/2" ceiling
thickness. Galvanized steel
c
onstruction.
P
laster frame features include:
• Regressed locking screw for
s
ecuring hanger bars.
• Cutouts for easily crimping
hanger bars in position.
• HALO name embossed on plaster
f
rame.
•The inner can housing may be
removed from the plaster frame
to provide access to the junction
box.
• Pre-installed AIR-TITE gasket.
Go t N AIL! ™ B ar Ha n g e r s
• Pre-installed nail easily installs in
regular lumber, engineered
lumber and laminated beams.
• Safety and guidance system
prevents snagging, ensures
smooth straight nail penetration
and allows bar hangers to be
easily removed if necessary.
• Automatic levelling flange aligns
the housing and lets you hold the
housing in place with one hand
while driving nails.
• Housing can be positioned at any
p
oint within 24" joist span
• Pass-N-Thru™ feature allows bar
h
angers to be shortened without
r
emoving from plaster frame.
• Score lines allow "tooless"
s
hortening for 12" joists.
• Bar hangers may be repositioned
9
0°.
•
IntegralT-bar clip snaps onto
T-bars - no additional clips
r
equired.
Ju n c tion B ox
• UL Listed for through branch
c
ircuit wiring (4 No. 12ga., 90°C
conductors).
• Four 1/2" trade size conduit
knockouts with true pry-out slots
are positioned to
accommodate straight conduit
runs.
•Three Slide-N-Side™ wire traps
allow non-metallic sheathed
cable to be installed without tools
and without removing knockouts.
Accepts a wide range of non-
metallic sheathed cable.
- Allows wiring connections to be
made outside the junction box
- Simply insert the cable directly
into the trap after connections are
made.
-Three push-in wire connectors
are included and eliminate the
need for separate wire nuts.
- Accommodates the following
s
tandard non-metallic sheathed
cable sizes:
(
US) #14/2, #14/3, #12/2, #12/3
(
Canada) #14/2, #14/3, #12/2
T
rans fo rmer
Integral magnetic transformer
s
teps 120V line voltage down to
1
2V lamp operating voltage.
So cket
GU5.3 socket for 12V MR16 lamps.
L
ab e l s
• UL/cUL Listed 1598 Luminaire
• UL/cUL Damp Location Listed
• UL/cUL Listed for FeedThrough
• UL/cUL Listed for Direct Contact
with Insulation and combustible
material
Meets following IC - AIR-TITE
requirements:
• State of CaliforniaTitle 24
• Washington State Energy Code
• International Energy Conservation
Code (IECC)
• NewYork State Energy
Conservation Construction Code
• Certified Under ASTM-E283 for
air tight construction.
H38LVICAT
3" Insulated Ceiling
AIR-TITE™ Recessed
Housing
12V MR16
3 " T R I M S
F O R U S E I N
I N S U L AT E D C E I L I N G S
C A N B E C O V E R E D W I T H
I N S U L AT I O N
Transformer Data:
Type: Magnetic
Primary: 120VAC, 60 Hz
Secondary: 11.5 ±0.3V
Features
• Slide-N-Side™ Junction Box
• GOT NAIL!™ Bar Hangers
• Pass-N-Thru™ Bar Hangers
• Regressed Locking Screw
• HALO ID on Plaster Frame
ADV060301
2010-08-26 12:52:52
Catalog #
T
ype
Date
P
roject
C
omments
Prepared by
3-3/4"
[95mm]
Ceiling
Opening
7 1/2"
[190mm]
T o p V i e w
9 1/8"
[231mm]
12 3/4"
[324mm]