Page V8-T6-3
Overview
A complete Zero Pressure Accumulation
(ZPA) sensing and control solution. This
system solves the problem of product
damage and mishandling caused by
mechanical sensor rollers on outdated
ZPA conveyors.
Conveyor Systems
Self-contained package includes sensor,
logic, air valve, and wiring
Non-contact, true Zero Pressure
Accumulation
Multiple algorithms available to provide
the exact functionality you require
Multiple wiring options available—
including NEMA
®
4 and NEMA 1 varieties
Low installation costs
Integrated “beam status” contact available
to allow direct integration into AC or DC
control systems
One-touch air fittings for quick installation
Low-profile package allows easy
integration into conveyor side-channel
System designed with sub-4A 24 Vdc
wiring for safety and reduced installation
costs
Easily interfaced to external control
systems for singulated discharge and/or
slug release
Highly optimized, low-cost power supply
Technical Data and Specifications
Operations—Warranted for up to 60
million operations (3 years)
Electrical ratings—
100 mA current switching capacity;
132 Vac/dc maximum switching voltage;
400V isolation; 10 mA maximum off-state
leakage; 25W maximum on-state
resistance
Enclosure ratings—
NEMA 1 and NEMA 4 (by model)
Approvals
cULus
Page V8-T6-14
Overview
A fully engineered non-contact,
photoelectric sensor system with built-In
accumulation control. This sensor system
solves the problem of product damage and
mishandling caused by mechanical sensor
rollers on outdated ZPA conveyors.
Conveyor Systems
Non-contact, true Zero Pressure
Accumulation control without a PLC
Multiple algorithms available to provide the
exact functionality you require
Additional gap and compression timing
versions available
Low installation costs with pre-measured
and connectorized wiring
Fits zone lengths between 18 and 60 inches
in 6-inch increments and conveyors up to
60 inches wide
Compatible with commonly available
solenoid-operated air valves
Sensors are short circuit protected with
automatic reset of sensor when short is
removed
System designed with sub-4A 24 Vdc
wiring for safety and reduced costs
Easily interfaced to external control
systems for singulated discharge and/or
slug release
Technical Data and Specifications
Operations—Warranted for up to 60
million operations (3 years)
Electrical ratings—
18 to 30 Vdc, 100 mA current switching
capacity; 10 mA maximum off-state
leakage; 8 mS response time; NPN or PNP
Enclosure ratings—NEMA 1
Material—Polycarbonate lens, cycoloy and
lexan body, glass-filled PCT connector
Approvals
Page V8-T6-25
Overview
Designed to be used with the 200 Series
and E68 Series Zero Pressure Accumulation
Systems, but is also suitable for use in a
wide variety of general material handling
applications. The unit delivers 100W output
at 27 Vdc and supports easy, Class II wiring
Sensors
Integrated AC junction box features for
one-step mounting and wiring without the
need for additional accessories or
enclosures
Built-in DC power health contact allows
easy monitoring of power supply status
Unique design features a tamper-proof
sealed construction to reduce the risk of
damage associated with conventional open
control-panel type supplies
Built-in slug-release input converts an AC
or DC input to the appropriate DC signal for
integration with the 200 Series and E68
Series Zero Pressure Accumulation
Systems
Dual output connection terminals to make it
easy and convenient to locate the power
supply at the center of the cable run
Technical Data and Specifications
Electrical ratings—100 to 250 Vac
operating voltage; 27 Vdc, 100 watt output;
15–132 Vac/dc 3 mA minimum slug input;
PNP or NPN, switch selectable
Enclosure ratings—NEMA 4X
Material—Aluminum
Approvals
cULus Class 2
Page V8-T6-28
Overview
Designed to be used with the 200 Series
and E68 Series Zero Pressure Accumulation
Systems, but is also suitable for use in a
wide variety of general material handling
applications. The unit delivers 100W output
at 27 Vdc and supports easy, Class II wiring
Sensors
Integrated AC junction box for one-step
mounting and wiring without the need for
additional accessories
Built-in DC power health contact allows
easy monitoring of power supply status
Unitized design features a tamper-proof
encapsulated construction to reduce the
risk of damage associated with
conventional open control-panel type
construction
Built-in slug-release input converts an AC
or DC input to the appropriate DC signal for
integration with the 200 Series and E68
Series Zero Pressure Accumulation
Systems
Dual output connection terminals to make it
easy and convenient to locate the power
supply at the center of the cable run
Technical Data and Specifications
Electrical ratings—
105 to 132 Vac operating voltage;
27 Vdc, 100 watt output; 15–132 Vac/dc
3 mA minimum slug input; PNP or NPN,
switch selectable
Enclosure ratings:—NEMA 1
Material—Die-cast aluminum
Approvals
UL
®
Listed
cUL
®
Approved