Data Sheet

DATASHEET - EMS2-RO-T-3-SWD
Reversing starter, 24 V DC, 0,18 - 3 A, Push in terminals, SmartWire-DT
slave
Part no. EMS2-RO-T-3-SWD
Catalog No. 192384
Alternate Catalog
No.
EMS2-RO-T-3-SWD
Delivery program
Product range Electronic motor starter
Product range SmartWire-DT slave
Subrange SmartWire-DT electronic motor starters
Basic function Reversing starters (complete devices)
Function For connecting to SmartWire-DT for expanded diagnostics
Description DOL starting
Reversing start
Motor protection
Circuit design: safety output stage with bypass, three-phase disconnect.
Motor current additionally adjustable via SmartWire-DT.
Messages Operational readiness
Operating direction feedback
Motor current in %
Motor current in A
Thermal motor image in %
Overload prewarning
Trip indications (overload, phase failure, etc.)
Set short-circuit release value
Device Type
Commands Operating the motor starter
Manual reset
Automatic reset
Motor ratings
Max. rating for three-phase motors, 50 - 60 Hz
AC-53a
380 V 400 V 415 V P kW 0.06 - 1.1
Setting range of overload releases I
r
A_x 0,18 - 3
Actuating voltage 24 V DC
Connection technique Push in terminals
Connection to SmartWire-DT yes
Technical data
General
Standards IEC/EN 60947-4-2
UL508
Ambient temperature
Storage °C
Min. ambient temperature, storage °C - 40
Ambient temperature, storage max. °C + 80
Open °C
Operating ambient temperature min. °C -5
Operating ambient temperature max. °C + 55
Weight kg 0.22
Mounting Top-hat rail IEC/EN 60715, 35 mm
Protection type (IEC/EN 60529, EN50178, VBG 4) IP20
Mounting position Vertical
Motor feeder at bottom
Terminal capacity
06/18/2021 Eaton 192384 ED2021 V80.0 EN 1 / 5