Data Sheet

Design verification as per IEC/EN 61439
Technical data for design verification
Operating ambient temperature min. °C -25
Operating ambient temperature max. °C 70
Impact resistance IK06 according to EN 50102
Technical data ETIM 7.0
Low-voltage industrial components (EG000017) / Enclosure for control circuit devices (EC000200)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Command and alarm device / Housing for command and alarm devices
(ecl@ss10.0.1-27-37-12-05 [AKF023014])
Number of command positions 4
Construction type housing Surface mounting housing
Material housing Plastic
Material quality housing Other
Diameter openings mm 22.5
Colour housing cover Grey
Degree of protection (IP) IP67/IP69K
Degree of protection (NEMA) Other
Width mm 43
Height mm 301
Depth mm 44
Approvals
Product Standards IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
UL File No. E29184
UL Category Control No. NKCR
CSA File No. 012528
CSA Class No. 3211-03
North America Certification UL listed, CSA certified
Degree of Protection UL/CSA Type 1, 4X Indoor
06/18/2021 Eaton Y7-197234 ED2021 V80.0 EN 2 / 4