Specifications

8
EATON Power Xpert 9395 UPS Eaton.com/9395
Batteries: the heart of every UPS
When a utility power outage causes a UPS to switch to battery
power, it's imperative that those batteries are healthy, charged and
UPTOTHETASK)MPROPERBATTERYMANAGEMENTISTHENUMBERONE
cause of downtime. Many UPS batteries on the market today are
constantly trickle-charged—a process that degrades the battery’s
internal chemical composition over time, reducing potential
battery service life by as much as 50 percent. To address this, the
9395 uses a sensing circuit and innovative three-stage charging
TECHNIQUETOSIGNIlCANTLYEXTENDBATTERYSERVICELIFEANDOPTIMIZE
RECHARGETIME)NADDITIONTEMPERATURECOMPENSATEDCHARGING
monitors temperature changes, and adjusts the rate of charge to
prolong battery life.
Monitor batteries for optimum readiness
Advances in firmware and digital technology enable the 9395 to
offer sophisticated battery monitoring and management features
you might expect to find only on expensive add-on systems,
including:
s2EMAININGBATTERYRUNTIMEISCALCULATEDBYUSINGSYSTEMLOADING
and trended battery discharge data, plus internal sensing points
for voltage and current data.
s"ATTERYCIRCUITTESTAPERIODICFULLLOADTESTOFTHEBATTERYSTRING
is done to ensure there are no open circuits or weak cells that
WOULDJEOPARDIZEBATTERYPERFORMANCEANDSYSTEMAVAILABILITY
)NADDITIONTOTHESEINTEGRATEDMONITORINGFEATURESWEOFFER
ONEYEAROFSECUREREMOTEMONITORINGTOPROVIDEXREALTIME
MONITORINGOFMORETHAN503ANDBATTERYALARMSWITHE.OTIFY
This real-time information is critical to help you make management
decisions, from scheduling preventive maintenance to determining
the best way to reduce loads during an outage.
"YENSURINGOPTIMALBATTERYHEALTHANDAVAILABILITYBATTERY
monitoring features raise the reliability of the 9395 beyond any
other UPS in its class.
Service and support enhance performance
%ATONRECOGNIZESTHATSUPERIORPOWERRELIABILITYREQUIRESmAWLESS
EXECUTIONFROMOURSERVICETEAM)NCLUDEDATNOEXTRACHARGEWITH
every 9395 is:
sXXSTARTUPSERVICEANDCUSTOMERTRAINING
s/NEYEARLIMITEDFACTORYWARRANTY
s3ERVICEPROTECTIONPLANXCOVERAGEEIGHTHOURRESPONSE
(upgrade to four- or two-hour where available), parts and labor,
unlimited on-site emergency response support
sE.OTIFY2EMOTE-ONITORING3ERVICEXCRITICALALARM
notification and monthly reports on UPS and battery health
sXTECHNICALSUPPORTACCESS
)NADDITIONTOTHEWARRANTYANDlRSTYEAROFONSITECOVERAGE
Eaton offers a wide variety of support agreements for continued
preventive and emergency response maintenance. PowerTrust
Service Plans include:
s503ANDBATTERYSCHEDULEDPREVENTIVEMAINTENANCE
s0ARTSANDLABORCOVERAGEFORELECTRONICSANDORBATTERIES
s&ACTORYTRAINEDTECHNICIANSWITHGENUINE%ATONPARTSAND
diagnostic tools
sE.OTIFY2EMOTE-ONITORING3ERVICE
s!VAILABLECOVERAGEXEIGHTFOURTWOHOURRESPONSEORX
next business day response
sXTECHNICALSUPPORTACCESS
1. Refer to the Eaton Corporation Limited Factory Warranty for
three-phase UPS products for specifications, limitations, and terms.
Service and support specifications may vary by country.
“We’ve been very pleased with the support
we receive whenever we call. Because we
rely heavily on the unit, and since we don’t
have the onsite expertise or staff to
maintain it, having a service plan gives us
additional peace of mind to know that it is
being well maintained.”
- Dean Kokko, wager operations manager, TVG