Eaton, X-Slot, PowerVision and Foreseer,
are trade names, trademarks and/or
service marks of Eaton Corporation or
its subsidiaries and affiliates.
All other trademarks are the property
of their respective owners.
©2011 Eaton Corporation
All Rights Reserved
Printed in USA
IGS02ENM
July 2011
Technical Specifications
General
UL and cUL listed
Up to 252 branch circuits monitored on a single display
Input Monitoring
Three-phase voltage: RMS L-L, RMS L-N, RMS %, THD % and frequency
Three-phase current: RMS, RMS %, THD %, Crest Factor
Power: kW, kVA, PF (when input CT option is installed)
Monthly profiling: Time-stamped Min V, Max V, Min I, Max I, Max THD, Min kVA,
Max kVA, Power Factor
Active alarms and event logging: Input ACUV, Input ACOV, Input UFOF, Input Phase
Rotation, Input Phase Loss, THD
Output Monitoring
Three-phase voltage: RMS L-L, RMS L-N, RMS %, THD % and Frequency
Three-phase current: RMS, RMS %, THD %, Crest Factor
Power metering (kW, kVA, PF)
Power usage (kWH): Monthly, Yearly, Total, Non-volatile
Monthly profiling: Time-stamped Min V, Max V, Min I, Max I, Max THD, Min kVA,
Max kVA
Active alarms and event logging: Output ACUV, Output ACOV, Output UFOF, Output
Phase Rotation, Three Level Phase Overload, THD, phase loss
System Monitoring
Non-volatile real-time clock
Ground current: RMS
Neutral current: RMS
Monthly profiling: Time-stamped, minimum and maximum ground and
neutral current
Active alarms and event logging: ground/neutral current warning, ground
current overload, neutral current warning, neutral current overload, transformer
over-temperature warning, transformer over-temperature, SPD failure, input
breaker open, input breaker tripped, Emergency Power Off, building alarm 1 to 4
(Alarm names for building alarms are programmable by user)
Controls (Optional)
Emergency Power Off
Remote Emergency Power Off
Manual restart
Phase loss protection
Ground fault detection
Environmental parameters (used with EMP and PXGX 1000 card)
Unit temperature calculated in metric or standard (°F and °C)
Optional Transformer (if applicable) temperature (°F and °C)
Optional Humidity within the unit (%)
Individual panel or sub-feed breaker monitoring (42 positions each Panel)
One-, two- or three-phase current: RMS, RMS%
Power: kW, kVA, PF
Power usage (kWH): monthly, yearly, total
Max current/phase, Wmax, VAmax, PFmin, Active alarms and event logging: panel
breaker overload warning, panel breaker overload
User can easily add panel breakers
User configurations: breaker rating, number of phases, position, breaker overload
alarms, breaker overload warning level
User interfaces
Eight-line by 40-charater LCD local display
Four indicator lamps and alarm horn
Optional emergency power-off switch
Communications
Two serial ports, one shared RS232/X-Slot plus one X-Slot for communication
expansion
Standard output alarm relay
Optional X-Slot modbus RTU card
Optional X-Slot PXGX 1000 card
Due to continuing product improvements specifications are subject to change and new features may be