Cut Sheet

C30CN Electrically and
Mechanically Held – Overview
For effi cient control of industrial,
commercial and outdoor lighting
applications
Modular design with up to 12 power poles
(30A per pole max.), fl exibility to
add/remove poles
C30CN Components – Model Selection
Mechanically Held Module Kits – Overview
These kits are for converting electrically
held contactors to mechanically held
units. Kits include control module,
latch, latch cover and auxiliary
contacts plus installation instructions.
Mechanically Held Kits – Model Selection
Coil Volts Control Volts Catalog Number
2-Wire
24-277V AC 110-120V AC C320MH2WA0
200-277V AC C320MH2WH0
24V AC C320MH2WT0
12-24V DC C320MH2WT1
3-Wire
24-277V AC 110-120V AC C320MH3WA0
200-277V AC C320MH3WH0
24V AC C320MH3WT0
12-24V DC C320MH3WT1
Power Poles – Overview
The C30CN contactor accepts up to a maximum
six single- or double-pole (or combinations) power
poles. These can be used to form up to:
12 NO poles max. when six double-poles are
used in NO positions (1-6)
8 NC poles max. with four double-poles in the
NC position (1-4) and four NO poles with two
double-poles in the two NO positions (5-6)
Power Poles – Model Selection
Power Poles Catalog Number
Single-Pole C320PRP1
Double-Pole C320PRP2
Quick Selector TD03701001E Effective April 2009
Lighting Contactors for
the Construction Market
Electrically Held Base Contactor – Overview
The C30CNE20_0 electrically held
base contactor contains a 2NO
power pole as standard and will
allow the addition of power poles to
build an electrically held contactor up
to 12 poles maximum. A mechanically held mod-
ule kit can also be added to convert the electrically
held contactor to mechanically held in the fi eld.
Electrically Held Base Contactor –
Model Selection
Power Poles Catalog Number
1
2NO C30CNE20_0
1
When ordering, replace magnet coil alpha designation in catalog number
(_) with proper code suffi x from table below.
Electrically Held Base Contactor – Coil Voltage
Coil Voltage/Hertz
Code
Suffi x Coil Voltage/Hertz
Code
Suffi x
115-120/60, 110/50 A 265-277/60, 240/50 H
230-240/60, 220/50 B 24/60, 20/50 T
460-480/60, 440/50 C 28/60, 24/50 V
575-600/60, 550/50 D 347/60 X
200-208/60 E
Auxiliary Contacts – Model Selection
Auxiliary Block Catalog Number
Single-Pole C320AMH1
Double-Pole C320AMH2
Power poles convert from NO to NC with
a simple 180 degree turn
Field convertible from electrically held to
mechanically held and vice versa
Suitable for tungsten, ballast, HID, and
non-motor AC resistive loads

Summary of content (2 pages)