Product Overview

Eaton Corporation
Electrical Group
1000 Cherrington Parkway
Moon Township, PA 15108
United States
877-ETN-CARE (877-386-2273)
Eaton.com
© 2009 Eaton Corporation
All Rights Reserved
Publication No. TD03301007E
April 2009
PowerChain Management is a registered
trademark of Eaton Corporation.
All other trademarks are property of their
respective owners.
Quick Selector TD03301007E
April 2009
NEMA Contactors for
the Construction Market
Freedom Series NEMA Starters – Overview
Three-phase, full voltage magnetic starters most commonly used to switch AC
motor loads
Bimetallic ambient compensated overload relays
These overload relays feature:
Interchangeable heater packs adjustable ±24% to match motor FLA
Selectable manual or automatic reset operation
Single-phase protection, Class 20 or Class 10 trip time
Overload trip indication
Electrically isolated NO-NC contacts (pull RESET button to test)
Also available with solid-state overload relays (see Tab 33 of the Control Products & Services Catalog, CA08102001E)
Type AN16/An56 NEMA Starters – Model Selection
NEMA
Size
Continuous
Ampere
Rating
Service-Limit
Current Ratings
2
Maximum UL Horsepower
3-Pole Non-Reversing 3-Pole Reversing Vertical Reversing1-Phase 3-Phase
115V 230V 208V 240V 480V 600V Catalog Number
1
Catalog Number
1
Catalog Number
1
00 9 11 1/3 1 1-1/2 1-1/2 2 2 AN16AN0_C AN56AN0_C
0 18 21 123355AN16BN0_C An56BN0_C AN56BNV0_
1 27 32 2 3 7-1/2 7-1/2 10 10 AN16DN0_B AN56DN0_B AN56DNV0_
2 45 52 3 7-1/2 10 15 25 25 AN16GN0_B AN56GN0_B AN56GNV0_
3 90 104 25 30 50 50 AN16KN0_ AN56KN0_ AN56KNV0_
4 135 156 40 50 100 100 AN16NN0_ AN56NN0_ AN56NNV0_
5 270 311 75 100 200 200 AN16SN0_B AN56SN0_B
6 540 621 150 200 400 400 AN16TN0_C AN56TN0_B
7 810 932 200 300 600 600 AN16UN0_B AN56UN0_B
8
3
1215 1400 400 450 900 900 AN16VN0_B AN56VN0_B
1
When ordering, replace magnet coil alpha designation in catalog number (_) with proper code suffi x from table below.
2
The service-limit current ratings represent the maximum RMS current, in amperes, which the controller shall be permitted to carry for protracted periods in normal service. At service-limit current ratings, termperature
rises shall be permitted to exceed those obtained by testing the controller at its continuous current rating. The current rating of overload relays or trip current of other motor protective devices used shall not exceed
the service-limit current rating of the controller.
3
Common control. For separate 120V control, insert letter D in seventh position of listed catalog number (ex. CN15VND3C).
Magnet Coils (AC and DC) –
Model Selection
Coil Volts and
Hertz Code Suffi x
Coil Volts and
Hertz Code Suffi x
120/60, 110/50
240/60, 220/50
480/60, 440/50
600/60, 550/50
A
B
C
D
380-415/50
550/50
24/60, 24/50
5
24/50
L
N
T
U
208/60
277/60
208-240/60
4
240/50
E
H
J
K
32/50
48/60
48/50
V
W
Y
4
NEMA Sizes 00 and 0 only.
5
NEMA Sizes 00 and 0 only. Sizes 1 through 8 are 24/60 only.
Freedom Series
Non-Reversing Starter
NEMA Size 1
Freedom Series
Reversing Starter
NEMA Size 1
Freedom Series
Auxiliary Contacts
Auxiliary Contacts –
Model Selection
Side-Mounted, NEMA Sizes 00 to 2, IEC Sizes A to K
Description
Contact Confi guration
Code
6
Catalog Number
1NO
1NC
10
01
C320KGS1
C320KGS2
1NO-1NC
2NO
2NC
1NO-1NCI
1NO (EC) - 1NC (LO)
1NCI
11
20
02
N/A
N/A
N/A
C320KGS3
C320KGS4
C320KGS5
C320KGS6
C320KGS7
C320KGS8
6
This two-digit code is found on the auxiliary contact to assist in identifying the specifi c
contact confi guration. The fi rst digit indicates the quantity of NO contacts and the
second indicates the quantity of NC contacts.
Additional Freedom Series auxiliary contacts are available in
NEMA sizes 3 to 8 and IEC sizes L to Z. For a complete listing of
these accessories, see the Control Products & Services Catalog
(CA08102001E), Tab 33.