Cut Sheet

V1-T1-54 Volume 1—Residential and Light Commercial CA08100002E—April 2019 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Single-Phase—Main Lug Loadcenters
Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral, continued
Single-Phase—Main Lug Loadcenters—400 and 600 A
Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral
Notes
1
Ground bar kits priced separately unless otherwise noted. See Page V1-T1-72.
2
Has notch for BRPHD hold-down kit in 125A and 200A styles.
3
Combination cover style.
4
Suitable for use as service equipment when not more than six main disconnecting means are provided.
5
Ground bars installed.
6
Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-71.
7
Includes main lugs. Loadcenters can convert to main breaker using kit.
8
Comes with a white cover
9
These styles will be replaced in 2019 with new plug-on neutral style loadcenter.
Main
Ampere Rating
Maximum Number
1-Inch (25.4 mm)
Enclosure
Typ e
Box
Size
Wire Size Range
Cu/Al 60 °C or 75 °C
for Main Lugs
Loadcenter
Catalog Number
17
Spaces Circuits
125 12 24 Indoor X0 #6–2/0 BRP12L125
234
12 24 Indoor X0 BRP12L125G
234
12 24 Indoor X0 BRP12L125DG
2345
12 24 Outdoor B1R BR1224L125R
2468
16 32 Indoor X1 BRP16L125
234
16 32 Indoor X1 BRP16L125G
235
16 24 Outdoor B2R BR1624L125R
269
20 40 Indoor X2 BRP20L125
234
20 40 Indoor X2 BRP20L125G
235
20 24 Outdoor C1R BR2024L125R
269
24 48 Indoor X3 BRP24L125
23
24 48 Indoor X3 BRP24L125G
235
24 48 Indoor X3 BRP24L125GW
23458
30 60 Indoor BRP30L125
23
150 16 32 Indoor X3 #1–300 kcmil BRP16L150
3
20 40 Indoor X3 BRP20L150
3
20 40 Indoor X3 BRP20L150G
35
200 12 24 Outdoor B2R BR1224L200R
469
20 40 Indoor BRP20L200
3
20 40 Indoor BRP20L200G
35
20 40 Outdoor C3R BR2040L200R
69
24 48 Indoor X4 BRP24L200
3
30 60 Indoor X5 BRP30L200
3
30 60 Indoor X5 BRP30L200G
35
31 61 Indoor X5 BRP30L200GW
358
30 40 Outdoor D1R BR3040L200R
69
40 80 Indoor X6 BRP40L200
3
40 80 Indoor X6 BRP40L200G
35
40 40 Outdoor G1R BR4040L200R
69
Main
Ampere Rating
Maximum Number
1-Inch (25.4 mm)
Enclosure
Typ e
Box
Size
Wire Size Range
Cu/Al 60 °C or 75 °C
for Main Lugs
Commercial Loadcenter
Catalog Number
1
Spaces Circuits
With Flush or NEMA
Type 3R Cover
With Surface
Cover
400 12 24 Outdoor 42 (2) #3/0–400 kcmil BR1224L400R
45
42 42 Indoor 22 BR4242L400F BR4242L400S
42 42 Outdoor 46 BR4242L400R
4
600 42 42 Indoor 22 (2) #2–500 kcmil BR4242L600S
BRP12L125
BRP12L200R
4242DFN

Summary of content (1 pages)