Product Brochure

Premium Residential Products
Eaton has enhanced its Premium Type CH Residential Circuit
Breakers making the best even better. The Type CHF AFCI breakers
also include advanced electronics which reduce nuisance tripping
and a standard diagnostic LED indicating 1 of 7 trip codes. These
features further establish the CH series of products as “Best in Class.”
CHF Series Breaker Include:
•
Mechanical flag for trip indication
•
Exclusive “Trip to OFF” and simple 1-Step breaker reset
Typical Applications
•
Residential loadcenters and
meter breaker panels
•
Light commercial distribution
panels
•
Pool panels
•
Residential transfer switch
panels
•
Various OEM applications
AFCI Diagnostic
Trip Codes
•
Thermal trip/manual
disconnect - The breaker
has detected an overload,
short circuit or was
manually turned off
•
Low current arc – An arc
has been detected due
to a break in a single
conductor
•
High current arc - An
arc has been detected
between two conductors
•
Short delay - An electronic
backup to the short-circuit
mechanism
•
Overvoltage - Voltage of
160V rms or greater
•
Ground fault - Current
has found an alternate
path to ground
•
Self test failure - The
breaker continually tests
the internal electronics
and software to ensure
that the arc fault detec-
tion technology is
working properly
Thermal Magnetic Breakers
•
Tri-Drive Screw Accepts Flat,
Robertson or Phillips Drivers,
making it easier for electri-
cians to install
•
Space Saving ¾” Design -
Accommodates more breakers
per panel
•
One and two-pole breakers
up to 50A
•
CH non flag versions available
up to 125A in two-pole and
100A in three-pole
Standard Features and Benets:
1
Type CH
Arc Fault and Ground Fault Breakers (AFCI/GFCI)
AFCI
1
•
Advanced electronics to
reduce unwanted tripping
from non-compliant devices
•
Standard LED indicates one
of seven trip codes to simplify
circuit diagnostics
•
Trip codes are stored per-
manently into the breaker’s
memory, to help identify
“trip” history
•
Branch overvoltage protection
for sensitive electronics
•
Meets areas requiring AFCI
protection under the 2008
and all subsequent editions
of the NECT
•
One pole breakers 15A
and 20A
GFCI
1
•
One pole breakers
15–30A
•
5mA protection per UL943
Optional Plug-on Neutral
•
Time savings up to 25% per
AFCI and GFCI installation
•
Improved wireway access
•
Easier troubleshooting due
to less wiring
•
Eliminates unwanted
tripping due to loose
pigtail connections
Standard Features and Benets:
CHF Circuit Breakers
Plug-on Neutral Breakers
Pigtail Breakers
Please reference catalog CA08100002E for additional ratings and configurations.
1
3
EATON CORPORATION Eaton Circuit Breakers and Loadcenters