2.1
Surge Protection
Surge Protection Devices and Lightning Arresters
Contents
Description Page
Surge Protection Devices and Lightning Arresters
Standards and Certifications . . . . . . . . . . . . . . . V1-T2-3
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V1-T2-4
Product Description
Due to the evolution
of electronics and
microprocessors in the
home, there is a continuous
challenge to provide quality
(clean) power for electronic
loads such as appliances,
computers/home office and
entertainment systems.
Surges caused by lightning,
utility grid switching and
other sources travel on
current carrying conductors
throughout the home, which
can affect and destroy
sensitive electronic loads.
Eaton offers a comprehensive
family of surge products for
use at service entrances.
These products can help
protect sensitive electronics
against the damaging effects
of surges.
Application Description
Two-Stage Protection
Two stages of surge
suppression are
recommended to provide
the best protection for
electronic equipment.
Two-stage surge suppression
should be provided for all
cables entering a home,
including power, Internet,
coaxial and telephone.
Service Entrance Surge
Protection
Eaton’s service entrance
surge protection units
provide premier surge
protection for AC power
at the service entrance.
These products provide
protection for residential
electrical equipment by
reducing power surges
to an acceptable level for
surge strips to handle at
the point of use.
UL 1449 3rd Edition Type 1 and
Type 2 Surge Protection
Type 1 Surge Protective
Device (SPD)
Permanently connected
Type 1 SPDs are intended
for installation between the
secondary of the service
transformer and the line
side of the service
equipment overcurrent
device, as well as the load
side, including watt-hour
meter socket enclosures,
and are intended to be
installed without an
external overcurrent
protective device.
Type 1 devices are
dual-rated for Type 2
applications as well,
providing the highest
ratings available for
installation at the service
entrance
Eatons CHSPT1
products provide Type 1
surge protection in
accordance with UL
®
1449 3rd Edition. These
units can be universally
mounted outside any
manufacturer’s primary
service equipment
Type 2 Surge Protective
Device—Permanently
connected Type 2 SPDs
are intended for installation
on the load side of the
service equipment
overcurrent device,
including SPDs located at
the branch panel
CHSPT2 products provide
Type 2 surge protection in
accordance with UL 1449
3rd Edition. These units
can be mounted outside
of any manufacturers
loadcenter or inside an
Eaton Surge/Surge Ready
loadcenter. Eaton also
offers accessories to the
CHSPT2 line for
telephone and cable
protection
Factory-Installed Surge
Protection—Eatons
loadcenters with factory-
installed surge protection
include a CHSPT2ULTRA
and a two-pole 50 A circuit
breaker. These loadcenters
increase the effectiveness
of surge protection due
to reduced lead length.
A modified deadfront
allows for easy viewing
of indicating lights for
status indication
Surge Panel
Surge Ready
Loadcenter—The Surge
Ready loadcenter provides
a mounting provision for
the CHSPT2ULTRA. This
loadcenter has a modified
deadfront to allow for
viewing of indicating lights