3.1
Residential Standby Backup Power Solutions
Standby Generators
Catalog Number Selection
Air-Cooled Generators
Liquid-Cooled Generators
Product Selection
Air-Cooled Generators
Notes
1
Battery to be furnished by others. Recommended size: Group 26R, 12 V, 225 CCA min.
2
Includes base fascia (No. EGENFASCIA) as standard.
Type
Eaton generator
EGENX Series
Rated Power
(LP/NG)
8 = 8/7 kW
11 = 11/10 kW
16 = 16/16 kW
20 = 20/18 kW
22 = 22/19.5 kW
EGENX 22 A
Enclosure
A = Aluminum
Blank = Steel
kW Rating
22
25
27
30
36
45
48
60
70
80
100
130
150
Voltage Required
A = Single-phase 120/240 V
G = Three-phase 208 V
J = Three-phase 240 V
K = Three-phase 480 V
Enclosure
A = Aluminum
S = Steel
Fuel Type
N = Natural gas
L = Liquid propane
SCAQMD Compliance
N = No
Y = Yes
EGEN 25 A N S Y
Rated
Power kW
(LP/NG)
Maximum Rated
Amperes
at 240 Vac
(LP/NG)
Main Line
Circuit Breaker
Amperes
Enclosure
Material
Engine
Size
Number of
Cylinders Fuel Type
GFI
Receptacle
SCAQMD
Compliant
Sound
Emissions
(dB at 7 m)
Limited
Warranty (yrs)
Catalog
Number
1
8/7 33.3/29.2 35 Steel 410 cc 1 Liquid propane/
natural gas
No Yes 62 5 EGENX8
11/10 45.8/41.7 50 Aluminum 530 cc 2 Liquid propane/
natural gas
No Yes 63 5 EGENX11A
16/16 66.6/66.6 65/55 Aluminum 992 cc 2 Liquid propane/
natural gas
No Yes 66 5 EGENX16A
20/18 83.3/75.0 90 Aluminum 999 cc 2 Liquid propane/
natural gas
Yes Yes 66 5 EGENX20A
2
22/19.5 91.7/81.2 100 Aluminum 999 cc 2 Liquid propane/
natural gas
Yes Yes 67 5 EGENX22A
2