Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers
Single-Phase—Main Lug Loadcenters
Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Single Neutral
Notes
1
Requires the use of Type CHT breakers.
2
Ground bar kits priced separately, see Page V1-T1-25.
– For 2/4 and 6/12 circuit loadcenters, use Type GBK5 or GBK520 ground bar
– For 4/8 and 8/16 circuit loadcenters, use Type GBK10 ground bar
– Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit loadcenters
3
Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
4
Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.
5
For use as service entrance applications only.
6
Neutral/ground holes (6) #14–6 and (3) #14–2/0 AWG Cu/AI.
7
Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting mains are
provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).
8
Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided and when not used as a lighting
and appliance panelboard (see Article 408.34 of the NEC).
Box sizes Pages V1-T1-27 and V1-T1-28.
Main
Ampere
Rating
Maximum Number
3/4-Inch (19.1 mm)
Enclosure
Type
Type of Trim
(Included)
Box
Size
Wire Size Range
Cu/Al 60 °C or 75 °C
for Main Lugs
Loadcenter
Catalog NumberSpace Poles
40 2 4
1
Indoor Surface (no door) 5 #14–6 CH2L40SP
23
24
1
Outdoor 5R #14–6 CH2L40RP
234
24
1
Indoor Flush (no door) 5 #14–6 CH2L40FP
23
70 2 4
1
Indoor Surface (no door) 5 #14–2 CH2L70SP
23
24
1
Outdoor 5R #14–2 CH2L70RP
234
24
1
Indoor Flush (no door) 5 #14–2 CH2L70FP
23
125 2 4
1
Indoor Surface (no door) 6 #14–1/0 CH2L125SP
23
24
1
Outdoor 6R #14–1/0 CH2L125RP
234
2 2 Outdoor #14–1/0 CH2L125RSE2P
456
24
1
Indoor Flush (no door) 6 #14–1/0 CH2L125FP
23
48
1
Indoor Surface (no door) 7 #14–1/0 CH4L125SP
27
48
1
Outdoor 7R #14–1/0 CH4L125RP
247
48
1
Indoor Flush (no door) 7 #14–1/0 CH4L125FP
27
612
1
Outdoor 6R #14–1/0 CH6L125R
267
816
1
Indoor Surface (no door) 7 #6–1/0 CH8L125SP
28
816
1
Outdoor 7R #6–1/0 CH8L125RP
267
816
1
Indoor Flush (no door) 7 #6–1/0 CH8L125FP
28
Surface Outdoor
Flush Outdoor
Surface (No Door)
Flush (No Door)