Metering Products
Meter Breakers
Contents
Description Page
Residential Meter Breakers
Non-EUSERC Combination Service Entrance
Devices 100–200 A Styles . . . . . . . . . . . . . . . . . V1-T4-39
Meets EUSERC Requirements Service Entrance
Devices 100–225 A. . . . . . . . . . . . . . . . . . . . . . . V1-T4-48
West Coast All-In-One Design . . . . . . . . . . . . . . . V1-T4-59
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . V1-T4-65
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-75
Commercial Safety Sockets . . . . . . . . . . . . . . . . . V1-T4-83
CH Style Renovation Solutions . . . . . . . . . . . . . . . V1-T4-86
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . V1-T4-87
Residential Meter Breakers
Product Description
A meter breaker is service
entrance equipment that
consists of a single meter
socket and loadcenter (circuit
breaker distribution section)
or meter socket and main
breaker combined in one
enclosure. Sometimes called
Combos, All-in-Ones, Meter
Centers or Meter Mains,
these units are increasing in
popularity as the socket and
loadcenter or main breaker
are located in one location,
thus providing the contractor
with a labor and material
savings when installing.
Application Description
In addition to residential
installations, meter breakers
are equally applicable for rural
service entrance, mobile
homes and construction site
temporary power. Meter
breakers are most often sold
in the western, southwestern
and southeastern United
States. The popularity of
meter breakers is continuing
to increase as more utilities
deregulate and pass the
responsibility of supplying
watthour meter sockets on
to the electrical contractor.
Application Considerations
Eaton has the meter breaker
to meet your application,
offering:
Non-EUSERC
EUSERC/West Coast
House panels
Commercial safety socket
Non-EUSERC
(Page V1-T4-39)
Eaton’s line of non-EUSERC
meter breakers are designed
for customers served by
utilities that are not members
of EUSERC.
EUSERC/West Coast
(Page V1-T4-59)
Eaton’s line of EUSERC
required devices adhere to
the agreed upon standards.
EUSERC utilities are
predominately located in
the western United States,
but some eastern and
midwestern utilities are
also members. These units
can also be used in many
Non-EUSERC areas.
House Panels
(Page V1-T4-75)
CH and BR Styles
(Page V1-T4-76).
Meter breaker device rated
at 300–400 A. Applied in
EUSERC and non-EUSERC
areas.
Commercial Safety Sockets
(Page V1-T4-83)
Applied in EUSERC and
non-EUSERC service areas
and used in commercial
applications.
Features, Benefits
and Functions
Both Type BR and CH
branch circuit breaker
styles available
Meets latest NEC
wire bending space
requirements
Slotted sealing screws
at hub with sealing
provision provided
Surface units are supplied
with mounting tabs
Semi-flush units are
supplied with stucco flange
Meter socket ring
landing will accept
locking security rings
Overhead or underground
service
Fifth jaw can be installed in
the 3 o’clock or 9 o’clock
position
Semi-flush with nail flange
or surface mounting
Meter mounting and
underground pull sections
are utility sealable
Units are rated a minimum
of 10 kAIC; some units
are 22 kAIC
Numerous units supplied
with center keyhole for
ease of mounting
NEMA 3R rainproof
construction