Cut Sheet
Volume 1—Residential and Light Commercial CA08100002E—August 2015 www.eaton.com V1-T4-83
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4.9
Metering Products
Meter Breakers
Residential Meter Breakers
Contents
Description Page
Residential Meter Breakers . . . . . . . . . . . . . . . . . V1-T4-37
Non-EUSERC Combination Service Entrance
Devices 100–200 A Styles . . . . . . . . . . . . . . . . . V1-T4-39
Meets EUSERC Requirements Service Entrance
Devices 100–225 A. . . . . . . . . . . . . . . . . . . . . . . V1-T4-48
West Coast All-In-One Design . . . . . . . . . . . . . . . V1-T4-59
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . V1-T4-65
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-75
Commercial Safety Sockets
CH Style Renovation Solutions . . . . . . . . . . . . . . . V1-T4-86
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . V1-T4-87
Commercial Safety
Sockets
Product Description
A Commercial Safety
Socket is service entrance
equipment that consists of
a commercial meter socket
with a test block, and may
come with or without a
loadcenter type distribution
section.
Application Description
Eaton’s Commercial Safety
Sockets are typically used
where a single meter socket
or single meter socket with
a distribution section are
needed. These areas could
include a commercial
business, commercial office
building, individual retail
facilities and signs and street
lighting. Commercial Safety
Sockets are typically used in
EUSERC utility regions.
Features, Benefits and Functions
Commercial Safety Sockets with
No Secondary Feeder
●
Ring type continuous duty
meter socket. 600 Vac
maximum, single- or
three-phase
●
100 and 200 A units
●
Bussed connection from
meter socket to test block
●
For use with self-contained
watthour meter
●
Conform with EUSERC
standards
●
NEMA 3R construction for
indoor/outdoor applications
●
Units can be individually
mounted with provisions
for hub kits and pole
mounting
Overhead Combination Units
●
NEMA 3R construction for
indoor/outdoor applications
●
T-fuse protection, 480 Vac
maximum
●
Line at top, load at bottom
●
100 and 200 A units
available up to 480 Vac
maximum
●
Circuit breaker protection
to 480 Vac maximum in
10, 22, 42 and 100 kAIC
ratings
●
Factory-cabled connection
from test block to line side
of tenant main
Underground Combination Units
●
100 and 200 A units
●
480 Vac maximum
●
NEMA 3R construction for
indoor/outdoor applications
●
Underground or overhead
feed
●
Provisions for self-
contained watthour meter
●
Bussed connection from
meter socket to test block
●
Tenant main disconnects
are available with circuit
breakers up to 480 Vac
maximum and T-fuse
mains, 240 Vac maximum
●
Load wires can exit top