Cut Sheet

V1-T4-84 Volume 1—Residential and Light Commercial CA08100002E—August 2015 www.eaton.com
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4.9
Metering Products
Meter Breakers
Product Selection
Overhead and Underground Combination Units and Individual Units
Individual Safety Sockets—600 V Maximum—No Secondary Feeder Devices
1
Commercial Safety Sockets with Provision for Main Circuit Breaker
3
Commercial Safety Sockets with Main Circuit Breaker Included
3
Notes
1
Reference drawing EUSERC DWG-305, G1.
2
If being protected by a fuse, the interrupting rating of the unit is limited to the fuse AIC rating. If being protected by a single- or three-phase,
600 V breaker, the AIC is 14 kA; by a maximum 400 A, single-phase, 240 V breaker, the AIC is 18 kA; by a maximum 200 A, single- or three-phase,
240 V breaker, the AIC is 18 kA; by a maximum 125 A, single-phase, 240 V breaker, the AIC is 22 kA.
3
Reference drawing EUSERC DWG-305A, G1.
4
Order plug-on Type BR, BRH or BRHH circuit breaker separately.
5
Order Type CC breaker or CCH breaker separately.
6
Type BR = 10 kA; Type BRH = 22 kA; Type BRHH = 42 kA.
7
Type CCV = 10 kA; Type CCVH = 25 kA.
Ampere
Rating
No. of
Jaws
AC
Voltage Service Phase, Wire
Maximum
Interrupting
Rating
Wire
Size
Catalog
Number
125 4 600 OH/UG Single-phase, three-wire
2
#14–2/0
CH114TB
125 5 600 OH/UG Three-phase, three-wire
2
#14–2/0
CH115TB
125 7 600 OH/UG Three-phase, four-wire
2
#14–2/0
CH117TB
200 4 600 OH/UG Single-phase, three-wire
2
#6–250 kcmil
CH124TB
200 5 600 OH/UG Three-phase, three-wire
2
#6–250 kcmil
CH125TB
200 7 600 OH/UG Three-phase, four-wire
2
#6–250 kcmil
CH127TB
Ampere
Rating
No. of
Jaws
AC
Voltage Service Phase, Wire
Feeder
Circuit
Breaker
Maximum
Interrupting
Rating
Wire
Size
Catalog
Number
125 4 240 OH Single-phase, three-wire Provision
46
#14–2/0
CH214MTBLB
125 7 208/120 OH Three-phase, four-wire Provision
46
#14–2/0
CH217MTBLB
125 4 240 UG Single-phase, three-wire Provision
46
#14–2/0
CHU214MTBLB
125 7 208/120 UG Three-phase, four-wire Provision
46
#14–2/0
CHU217MTBLB
200 4 120/240 OH Single-phase, three-wire Provision
57
#6–250 kcmil
CH224MTBLB
200 7 208/120 OH Three-phase, four-wire Provision
57
#6–250 kcmil
CH227MTBLB
200 4 120/240 UG Single-phase, three-wire Provision
57
#6–250 kcmil
CHU224MTBLB
200 7 208/120 UG Three-phase, four-wire Provision
57
#6–250 kcmil
CHU227MTBLB
Ampere
Rating
No. of
Jaws
AC
Voltage Service Phase, Wire
Feeder
Circuit
Breaker
Maximum
Interrupting
Rating
Wire
Size
Catalog
Number
100 7 480/277 OH Three-phase, four-wire EHD3100 14 kA #14–2/0
CH217MTBM515
100 7 480/277 UG Three-phase, four-wire EHD3100 14 kA #14–2/0
CHU217MTBMS15
200 7 480/277 OH Three-phase, four-wire JD3200 25 kA #6–250 kcmil
CH227MTBHMS15
200 7 480/277 UG Three-phase, four-wire JD3200 25 kA #6–250 kcmil
CHU227MTBHMS15
CH127TB