Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers
Contents—CH Specialty Products
Description Page
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2
CH Specialty Products
Spa Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-15
Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . V1-T1-17
Type CH Renovation Loadcenter
Type CH Retrofit Interior Kits . . . . . . . . . . . . . . V1-T1-19
CH Loadcenter Options and Accessories. . . . . . . . V1-T1-22
CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31
Type CH Renovation
Loadcenter
Product Description
Eaton’s Renovation
Loadcenter is designed
for the service contractor.
With the addition of a five-
circuit terminal block factory
mounted in the top left corner
of the loadcenter, the service
contractor can terminate
short-circuit wires instead of
having to use expensive wire
nuts. Also, the Renovation
Loadcenter incorporates a
twin-stacked neutral design
that places the neutral and
ground terminations higher in
the loadcenter. Both of these
features were added without
increasing any size from a
standard loadcenter. These
features will eliminate the
need for wire nuts and make
for a much neater installation.
There is a provision to field
mount a second five-circuit
terminal block (RN5TB) in
the top right corner of the
loadcenter. Choose amongst
Eaton’s Type CH breaker
family for use in the
Renovation Panel.
Product Selection
Single-Phase—Main Circuit Breaker Loadcenters 25 kAIC
1
Single-Phase, Three-Wire—120/240 Vac—Stacked Split Neutral
Branch Circuit Breakers (CH)
See Pages V1-T1-2–V1-T1-13.
Renovation Loadcenter
Notes
1
100 A main breaker is rated 10 kAIC.
2
Combination style covers may be used in surface or flush applications.
All main circuit breaker loadcenters are listed for use as service entrance equipment. Loadcenters
are factory-bonded for service entrance applications. Remove bonding strap for separate neutral
and ground bars for sub-feed applications.
Main
Breaker
Typ e
Main
Ampere
Rating
Max.
Number
3/4-Inch
(19.1 mm)
of Poles
Enclosure
Type
Box
Size
Wire Size
Range
Cu/Al
60 °C or 70 °C
for Main
Breakers
Loadcenter
Catalog
Number
Cover Catalog
Number
2
Combination Surface
CH 100 20 Indoor C #6–1/0 CH22B100CRN CH8CFF CH8CS
CSR 150 32 Indoor J #2–300 kcmil CH32B150JRN CH8JF CH8JS
CSR 200 32 Indoor J #2–300 kcmil CH32B200JRN CH8J CH8JS
CSR 200 42 Indoor K #2–300 kcmil CH42B200KRN CH8KF CH8KS
Description Catalog Number
Five-circuit terminal block kit
Ground bar kits (two maximum per panel)
RN5TB
(See Page V1-T1-25)