4.10
Metering Products
Group Metering
Contents
Description Page
Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V1-T4-88
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-90
Type CCV 120/240 V Tenant Main Circuit Breaker. . V1-T4-95
Type CV 120/240 V Tenant Main Circuit Breaker . . . V1-T4-96
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers. . . . . . . . . . . . . . . . . . . . .
V1-T4-98
Main Service Modules . . . . . . . . . . . . . . . . . . . . . . V1-T4-101
Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-115
Group Metering Inline Current Transformer
Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V1-T4-116
Residential Meter Stacks . . . . . . . . . . . . . . . . . . . . V1-T4-118
1MP, 1MM and 3MM Main Tenant
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . .
V1-T4-127
Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . . V1-T4-128
Commercial Meter Stack Modules . . . . . . . . . . . . . V1-T4-129
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . . .
V1-T4-136
Type CV 120/240 V Tenant Main Circuit Breaker
Product Overview
Eaton offers Type CCV
(10 and 22 kAIC) and Type CV
(42, 65 and 100 kAIC) family
of circuit breakers as the
primary tenant main breakers
used in most group metering
applications.
Product Description
Eaton’s residential products
Type CV molded-case circuit
breaker is available in two-
and three-pole configurations
from 60 A to 225 A in 42, 65
and 100 kAIC ratings.
Features
Ratings—120/240 Vac,
two- and three-pole,
through 225 continuous
amperes, calibrated
at 40 °C
Tripping characteristics
thermal-magnetic trip,
calibrated and sealed after
assembly. Indirectly heated
thermal tripping bimetal
elements; includes push-
to-test button for routine
preventive maintenance
Interrupting capacity at
120/240 Vac
Type CVS—42,000 A
rms symmetrical
Type CV—65,000 A
rms symmetrical
Type CVH—100,000 A
rms symmetrical
Handles—trip-free with
ON-TRIPPED-OFF
positions. Reset past OFF
is required to latch breaker
contacts after tripping
Te r m i n a l s —standard
lugs (wire connectors)
suitable for copper or
aluminum wire
Standards and Certifications
Complies with UL Standard
489. Breakers are listed
under UL File #E7819