Cut Sheet

Volume 1—Residential and Light Commercial CA08100002E—August 2015 www.eaton.com V1-T4-101
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4.10
Metering Products
Group Metering
Contents
Description Page
Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V1-T4-88
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-90
Type CCV 120/240 V Tenant Main Circuit Breaker. . V1-T4-95
Type CV 120/240 V Tenant Main Circuit Breaker . . . V1-T4-96
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers. . . . . . . . . . . . . . . . . . . . .
V1-T4-98
Main Service Modules
Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V1-T4-115
Group Metering Inline Current Transformer
Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V1-T4-116
Residential Meter Stacks . . . . . . . . . . . . . . . . . . . . V1-T4-118
1MP, 1MM and 3MM Main Tenant
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . .
V1-T4-127
Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . . V1-T4-128
Commercial Meter Stack Modules . . . . . . . . . . . . . V1-T4-129
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . . .
V1-T4-136
Main Service Modules
Product Description
Main terminal box
Main circuit breaker
Main bolted pressure
switch
Main fusible switch
Main fusible switch with
pull box
Underground pull box
Application Description
Main Circuit Breakers with
Busway Connections
The Service Entrance Product
Team announces the
availability of both main
fusible switch and main
circuit breaker group
metering mains with busway
connections. This offering
provides us with the ability
to offer multiple tenant
metering in high rise
apartment buildings where
riser busway is used.
Features, Benefits and Functions
Eaton’s Main Service Module
Offering: main terminal/lug
compartment, main circuit
breaker, main fusible
switch, main bolted
pressure switch, main
fusible switch with pull
box (meets EUSERC
electrical requirements),
underground pull box
termination compartment
without cross bus (meets
EUSERC electrical
requirements)
Mechanically and
electrically built for use
with 1MM, 3MM, 35MM,
37MM, 35SS and 37SS
modular metering stacks
For integrated system
short-circuit ratings with
main devices, see series
ratings on Page V1-T4-144
All main service modules
include both left and right
horizontal bus closure
plates
Two-pole devices are
applied to single-phase,
three-wire, 120/240 V or
208Y/120 V systems,
three-pole devices to 208Y/
240 V or 120/240 V delta
systems
Single-phase mains couple
to any modular metering
stack (1MM, 3MM, 35MM,
37MM, 35SS and 37SS)
Three-phase mains require
three-phase bussed stacks.
These modular metering
stacks are 3MM, 35MM,
37MM, 35SS and 37SS
If the ampere rating of the
main service module is
greater than the horizontal
bus rating of the meter
stack (residential or
commercial), the main
service module must be
center fed. Examples:
1200 A Main Circuit
Breaker (1MCB1200R)
with an 800 A residential
stack (1MM512R). 1600 A
Main Terminal Box
(3MTB1600R) with a
1200 A residential stack
(3MM212R12)
Most main service
modules are available with
aluminum or copper bus
Main Circuit Breakers with
Busway Connections
Three-phase, 400–200 A
main circuit breakers
Three-phase, 400–800 A
main fusible switches
Simple bridge joint
connection
Variety of options:
Right or left mounting
Internal ground or
housing ground
The MFS/MCB and busway
connector are supplied
completely assembled