Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers
Type CH Retrofit Type CH Retrofit Interior Collar
Adjustable Interior and Assembly with Trim
Contents—CH Specialty Products
Description Page
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2
CH Specialty Products
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-15
Plug-On Neutral Loadcenter . . . . . . . . . . . . . . V1-T1-17
Type CH Renovation Loadcenter . . . . . . . . . . . V1-T1-18
Type CH Retrofit Interior Kits
CH Loadcenter Options and Accessories . . . . . . . V1-T1-22
CH Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31
Type CH Retrofit Interior Kits
Product Description
Eaton’s unique Retrofit
Interior allows the customer
to cost-effectively and safely
upgrade an electrical service
without removing the existing
enclosure from the wall.
Application Description
The Retrofit Interior is
designed and tested
specifically for renovating
an outdated electrical panel in
an apartment, a condominium
or a single family home.
These outdated panels are
being recognized by local
inspectors and other
authorities as a possible
hazard.
Opportunities to Retrofit
Single- or three-phase
Main lug only or main
breaker
Up to 42 circuits
Up to 225 A interiors,
400 A available upon
request
Available with CH breakers
(3/4-inch) with copper bus
or BR breakers (1-inch) with
aluminum bus
The minimum lifetime
warranty for residential
breakers shall be as
follows:
Limited lifetime
warranty on all CH
branch breakers and
loadcenters
Refer to Eaton for
complete warranty
details
Features and Benefits
Upgrading Existing Electrical
Infrastructure Is Simple
Replaces vintage brands
that have hard to find,
expensive replacement
breakers
Safely upgrade to arc fault
and ground fault breakers
to meet current electrical
codes
Maximizes number of
circuits available with
compact design
Eco-friendly in asbestos-
filled environments
Exclusive design
Save Time and Money
Throughout the Installation
Uses existing panel
box and wires
Eliminates expensive and
time-consuming drywall/
paint repair
Saves 2–3 hours of
installation time compared
to a complete panel
changeout
Eliminates precise
measurements with field-
adjustable kit
Detailed Product Guide
For questions about retrofit
solutions, contact the Lincoln
Flex Center at 800-330-6479 or
flexcenterlincoln@eaton.com.
Be sure to provide width,
height and depth of panel.
Standards and Certifications
Meets 2008/2011/2014 NEC
wire bending requirements.